Honeywell 10105/2/1 Fail-Safe High-Density Analog Input Module
10105/2/1
Fail-Safe High-Density Analog Input Module · sixteen-channel safe analog input
Lifecycle note: Use the unit nameplate and current Honeywell documentation as the final references before approving a replacement.
Product Condition
Original New with One Year WarrantyParts Available
In Stock and Same Day ShippingDelivery Mode
Shipping via DHL Fedex or UPS etcEmail:
sales17@amikon.cnWhatsapp/Mob:
+86 15359408275Fail-Safe High-Density Analog Input Module · Fail Safe Controller
Honeywell 10105/2/1 is a Fail-Safe High-Density Analog Input Module for Fail Safe Controller. The identification and system context on this page are aligned to official Honeywell product-family, lifecycle or hardware documentation.
Honeywell 10105/2/1 is a 16-channel fail-safe high-density analog input module with a 0 to 4.1 V input range, 12-bit conversion and module inaccuracy below 0.25%. The official data sheet specifies 5 VDC and 24 VDC power, AK1-6 safety classification—AK6 in redundant mode—and software version 500 or later. Current-loop field signals require the documented conversion and termination arrangement.
For replacement work, confirm the complete model, suffix, hardware revision, installed-system release, termination or connector arrangement and application before ordering.
| Manufacturer | Honeywell |
|---|---|
| Model | 10105/2/1 |
| Part number | 10105/2/1 |
| Product type | Fail-Safe High-Density Analog Input Module |
| Product family / system | Fail Safe Controller |
| Official module type | Fail-safe high-density analog input |
| Input channels | 16 |
| Input range | 0 to 4.1 V |
| Input resistance | > 1 MΩ |
| A/D converter | 12-bit |
| A/D converter inaccuracy | ±1 LSB |
| Module inaccuracy | < 0.25% |
| Absolute maximum input | ±36 VDC |
| Crosstalk between channels | > 60 dB |
| Power requirements | 5 VDC 35 mA and 24 VDC 35 mA |
| Space requirement | 4 TE, 3 HE (4 HP, 3U) |
| Safety class | AK1-6; AK6 in redundant mode |
| Software version | 500 or later |
| Field-signal conversion | 0(4)-20 mA conversion through the documented FTA/converter arrangement |
| Primary order check | Complete part number, suffix and hardware revision |
| Final compatibility reference | Installed-unit nameplate and current Honeywell documentation |
Confirm the current Honeywell lifecycle status, supported release and approved replacement path before ordering.
Honeywell 10105/2/1 is identified as a Fail-Safe High-Density Analog Input Module for Fail Safe Controller. Use the complete part number and installed-unit nameplate as the primary identification references.
Honeywell 10105/2/1 supports sixteen-channel safe analog input within Fail Safe Controller installed systems.
Honeywell 10105/2/1 is associated with Fail Safe Controller; confirm the installed platform and supported system release before replacement.
For Honeywell 10105/2/1, verify the complete part number, hardware revision, installed-system release, termination or connector arrangement, quantity, destination and a clear nameplate photo.
Honeywell 10105/2/1 is documented against Honeywell FSC 10105/2/1 Fail-Safe High-Density Analog Input Data Sheet. Use the current Honeywell document and installed-unit nameplate as the final references.
Check the full model, part-number suffix, hardware revision, product family and physical connector or termination arrangement.
Yes. Similar front labels do not prove interchangeability; suffix, revision, coating, termination and system-release differences can affect compatibility.
Do not assume a direct substitution. Compare the exact hardware and application requirements and confirm the approved replacement path.
Refer to Honeywell FSC 10105/2/1 Fail-Safe High-Density Analog Input Data Sheet. The current Honeywell document and the installed-unit nameplate remain the final references.
Send the model, complete part number, quantity, destination and nameplate photo. We will verify identification details before confirming availability and lead time.
Technical information is based on Honeywell FSC 10105/2/1 Fail-Safe High-Density Analog Input Data Sheet. Final suitability must be verified against the exact installed unit and current official Honeywell documentation.
Visit us
32D Guomao Building, No.388, Hubin South Road, Siming DistrictDisclaimer : Salesplcauto sells new and surplus products and develops channels for purchasing such products. This website has not been approved or recognized by any of the listed manufacturers or trademarks. Salesplcauto is not an authorized distributor, dealer, or representative of the products displayed on this website. All product names, trademarks, brands, and logos used on this website are the property of their respective owners. The description, explanation, or sale of products with these names, trademarks, brands, and logos is for identification purposes only and is not intended to indicate any association with or authorization from any rights holder.
Copyright @2026 SalesPlc Limited. Sitemap
/ Blog
/ XML
/ Terms And Conditions
/ Privacy Policy
Network Supported