KJ3221X1-BA1 12P2531X062 VE4035S2B1
Redundant 8-channel 4–20 mA HART analog output
Order note: Confirm the complete nameplate before shipment.
Product Condition
Original New with One Year WarrantyParts Available
In Stock and Same Day ShippingDelivery Mode
Shipping via DHL Fedex or UPS etcRedundant 8-channel 4–20 mA HART analog output
KJ3221X1-BA1 12P2531X062 VE4035S2B1 is identified as Redundant 8-channel 4–20 mA HART analog output for DeltaV M-series Traditional I/O.
Provides redundant standard termination for eight 4–20 mA HART analog output channels in DeltaV M-series I/O.
All technical values on this page are limited to manufacturer documentation. Confirm the complete nameplate, installed configuration and current project records before ordering or replacement.
| Manufacturer | Emerson |
|---|---|
| Hardware identity | KJ3221X1-BA1 |
| Manufacturing part | 12P2531X062 |
| Ordering model | VE4035S2B1 |
| Signal | 4–20 mA with HART |
| Channels | 8 |
| Configuration | Redundant standard I/O termination |
| DeltaV support | v10.3.1 and later |
| Earlier-version note | Request KJ3221X1-BA2 path |
Confirm DeltaV version, partner card, terminal arrangement, loop load and complete KJ/12P/VE identification.
Provides redundant standard termination for eight 4–20 mA HART analog output channels in DeltaV M-series I/O.
Retain the exact displayed identity “KJ3221X1-BA1 12P2531X062 VE4035S2B1” together with the manufacturer label, hardware revision and any converter or termination identity. Do not shorten the purchase description when exact replacement is required.
The official value is 12P2531X062. Use it only with the corresponding manufacturer configuration and verify the installed nameplate before design or replacement decisions.
The documented value is VE4035S2B1. Compare it with the cabinet, field wiring, mechanical arrangement and approved project documentation rather than relying on physical similarity.
Secure final control elements under the site procedure and preserve loop states before working on either redundant output path.
Confirm DeltaV version, partner card, terminal arrangement, loop load and complete KJ/12P/VE identification.
Earlier-version note is documented as Request KJ3221X1-BA2 path. The product label, enclosure conditions and hazardous-area approvals remain controlling for the installed unit.
Photograph the complete nameplate and inspect the model, suffixes, connectors, mechanical form, condition and supplied accessories. Quarantine any item whose identity differs from the purchase record.
Test output scaling, loop response, HART communication, diagnostics, redundancy transfer and return to automatic control.
Send the complete model, quantity, destination and nameplate photo. We will verify identification before confirming availability.
Visit us
32D Guomao Building, No.388, Hubin South Road, Siming DistrictDisclaimer : Salesplcauto sells new and surplus products and develops channels for purchasing such products. This website has not been approved or recognized by any of the listed manufacturers or trademarks. Salesplcauto is not an authorized distributor, dealer, or representative of the products displayed on this website. All product names, trademarks, brands, and logos used on this website are the property of their respective owners. The description, explanation, or sale of products with these names, trademarks, brands, and logos is for identification purposes only and is not intended to indicate any association with or authorization from any rights holder.
Copyright @2026 SalesPlc Limited. Sitemap
/ Blog
/ XML
/ Terms And Conditions
/ Privacy Policy
Network Supported