KJ4001X1-NB1 12P3368X022
Left 1-wide I/O carrier extender
Order note: Confirm the complete nameplate before shipment.
Product Condition
Original New with One Year WarrantyParts Available
In Stock and Same Day ShippingDelivery Mode
Shipping via DHL Fedex or UPS etcLeft 1-wide I/O carrier extender
KJ4001X1-NB1 12P3368X022 is identified as Left 1-wide I/O carrier extender for DeltaV M-series Carrier Hardware.
Continues the DeltaV LocalBus carrier arrangement from the left side using the documented 1-wide extender hardware.
All technical values on this page are limited to manufacturer documentation. Confirm the complete nameplate, installed configuration and current project records before ordering or replacement.
| Manufacturer | Emerson Automation Solutions |
|---|---|
| Model | KJ4001X1-NB1 |
| Product type | 1-wide I/O carrier extender left |
| LocalBus power | 12 VDC at 8 A |
| Ambient temperature | -40 to +70 °C |
| Shock | 10 g half-sine, 11 ms |
| Vibration | 1 mm p-p at 2–13.2 Hz; 0.7 g at 13.2–150 Hz |
| Humidity | 5–95%, non-condensing |
| Maximum combined length | 6.5 m |
| Inter-enclosure cable | Install in conduit |
Do not substitute a right-side extender; verify left orientation, full 12P3368X022 label and total carrier-extension length.
Continues the DeltaV LocalBus carrier arrangement from the left side using the documented 1-wide extender hardware.
Retain the exact displayed identity “KJ4001X1-NB1 12P3368X022” together with the manufacturer label, hardware revision and any converter or termination identity. Do not shorten the purchase description when exact replacement is required.
The official value is 1-wide I/O carrier extender left. Use it only with the corresponding manufacturer configuration and verify the installed nameplate before design or replacement decisions.
The documented value is 12 VDC at 8 A. Compare it with the cabinet, field wiring, mechanical arrangement and approved project documentation rather than relying on physical similarity.
De-energize system power before removing the unit or disconnecting carriers or LocalBus extender cables.
Do not substitute a right-side extender; verify left orientation, full 12P3368X022 label and total carrier-extension length.
Ambient temperature is documented as -40 to +70 °C. The product label, enclosure conditions and hazardous-area approvals remain controlling for the installed unit.
Photograph the complete nameplate and inspect the model, suffixes, connectors, mechanical form, condition and supplied accessories. Quarantine any item whose identity differs from the purchase record.
Check orientation, carrier seating, cable routing and conduit, restore power and confirm LocalBus communication and I/O health.
Send the complete model, quantity, destination and nameplate photo. We will verify identification before confirming availability.
Visit us
32D Guomao Building, No.388, Hubin South Road, Siming DistrictDisclaimer : Salesplcauto sells new and surplus products and develops channels for purchasing such products. This website has not been approved or recognized by any of the listed manufacturers or trademarks. Salesplcauto is not an authorized distributor, dealer, or representative of the products displayed on this website. All product names, trademarks, brands, and logos used on this website are the property of their respective owners. The description, explanation, or sale of products with these names, trademarks, brands, and logos is for identification purposes only and is not intended to indicate any association with or authorization from any rights holder.
Copyright @2026 SalesPlc Limited. Sitemap
/ Blog
/ XML
/ Terms And Conditions
/ Privacy Policy
Network Supported