KJ4010X1-BF1 12P0831X062
Left LocalBus Extender Cable Assembly · Left-side LocalBus extender for M-series carrier architecture
Order note: Confirm the complete identifier, installed hardware and wiring before replacement. No compatibility is inferred from a similar-looking model.
Product Condition
Original New with One Year WarrantyParts Available
In Stock and Same Day ShippingDelivery Mode
Shipping via DHL Fedex or UPS etcLeft LocalBus Extender Cable Assembly · DeltaV M-series Horizontal Carriers
KJ4010X1-BF1 12P0831X062 is a Left LocalBus Extender Cable Assembly for DeltaV M-series Horizontal Carriers. The complete identifier is retained exactly as supplied so procurement and engineering teams can compare it directly with the installed nameplate.
Left-side LocalBus extender for M-series carrier architecture. Selection must match the exact installed carrier, terminal block, keying, field wiring and system revision.
This page does not treat a similar KJ, KL, 12P or ordering code as interchangeable. A clear nameplate and connector photo is required before a replacement is confirmed.
| Manufacturer | Emerson |
|---|---|
| Exact model / part number | KJ4010X1-BF1 12P0831X062 |
| Product family | DeltaV M-series Horizontal Carriers |
| Product role | Left LocalBus Extender Cable Assembly |
| Exact part number | 12P0831X062 |
| Product role | Left LocalBus extender cable assembly |
| LocalBus rating | 12.6 V DC at 8 A |
| Maximum combined carrier/extender length | 6.5 m |
| Ambient temperature | -40 to +70 °C |
| Relative humidity | 5 to 95% non-condensing |
| Airborne contaminants | ISA-S71.04 Class G3 |
| Installation rule | Verify the exact nameplate, carrier, terminal block and keying before installation |
Confirm the complete installed configuration and manufacturer documentation before replacement, expansion or migration.
Compare every character of the model and part number with the installed nameplate. Also record the hardware revision, terminal block, keying, connector orientation and field wiring. Do not shorten or normalize the supplied identifier.
KJ4010X1-BF1 12P0831X062 is identified here as Left LocalBus Extender Cable Assembly. The application must remain within the product family and configuration defined by the exact model, product role and technical data shown on this page.
Similarity in appearance or the KJ prefix does not prove interchangeability. Verify the complete part number, I/O or carrier role, terminal block, rotary keying, power design and installed DeltaV system revision before replacement.
Isolate power as required by the manufacturer instructions, document existing wiring, confirm connector orientation and keying, inspect the carrier and terminal block, and verify the field-circuit ratings against the approved design.
Do not assume hot-swap permission. Treat the unit as non-hot-swappable unless the approved site procedure for the exact installed configuration explicitly permits energized replacement. Otherwise isolate both system and field power, verify zero energy and apply the required hazardous-area controls before removal or insertion.
Use only the terminal block, carrier or cable assembly approved for the exact model and signal type. Confirm the mechanical keying and order code from the installed assembly and approved site engineering records.
Verify identification, power and field wiring first. Then complete the site-approved diagnostics, channel or bus checks, alarm review and functional test before returning the loop or controller node to service.
Send the complete nameplate, quantity, destination, cabinet position and clear photographs of the front, side and connectors. The replacement decision should be based on the full identifier and installed configuration, not the short model alone.
Use the approved site maintenance plan and the unit condition observed during inspection. Do not disassemble modules described as having no user-serviceable parts. Channel calibration or loop verification, where applicable, remains a system and application task.
Record the complete nameplate identifier, hardware revision, installed carrier or terminal block, connector orientation and keying, field wiring, operating voltage and application. Compare these details with the technical data shown on this page before requesting a replacement.
Protect the unit from electrostatic discharge, moisture, contamination and mechanical impact. Secure connectors and terminal parts, retain identification labels and confirm the required condition and inspection record in the quotation.
Send the model, complete part number, quantity, destination and nameplate photo. We will verify identification details before confirming availability and lead time.
Technical information is based on Emerson DeltaV M-series I/O Subsystem Horizontal Carriers Product Data Sheet. Final suitability must be verified against the exact installed unit and current official documentation.
Visit us
32D Guomao Building, No.388, Hubin South Road, Siming DistrictDisclaimer : Salesplcauto sells new and surplus products and develops channels for purchasing such products. This website has not been approved or recognized by any of the listed manufacturers or trademarks. Salesplcauto is not an authorized distributor, dealer, or representative of the products displayed on this website. All product names, trademarks, brands, and logos used on this website are the property of their respective owners. The description, explanation, or sale of products with these names, trademarks, brands, and logos is for identification purposes only and is not intended to indicate any association with or authorization from any rights holder.
Copyright @2026 SalesPlc Limited. Sitemap
/ Blog
/ XML
/ Terms And Conditions
/ Privacy Policy
Network Supported