MC-TAOX12 51304335-125
Analog Output Field Termination Assembly · Analog Output Field Termination Assembly
Lifecycle note: Use the unit nameplate and current Honeywell documentation as final references before approving a replacement.
Product Condition
Original New with One Year WarrantyParts Available
In Stock and Same Day ShippingDelivery Mode
Shipping via DHL Fedex or UPS etcEmail:
sales17@amikon.cnWhatsapp/Mob:
+86 15359408275Analog Output Field Termination Assembly - Honeywell TDC 3000 / TPS Process Manager I/O
Honeywell MC-TAOX12 51304335-125 is presented as an analog output field termination assembly for an installed Process Manager or TPS I/O configuration. The complete model and part number must be treated as a single ordering identity.
Public Honeywell planning tables reviewed for this page do not clearly establish the exact MC-TAOX12 and 51304335-125 pairing. Channel count, terminal style, compliance status and coating therefore must be confirmed from the installed nameplate and project documentation rather than inferred from a nearby TAOX12 variant.
Before replacement, record the paired analog output IOP, cable number, terminal map, output range, load, grounding and cabinet position. Prove each configured loop and fail-state response after installation.
| Manufacturer | Honeywell |
|---|---|
| Complete model | MC-TAOX12 51304335-125 |
| Product type | Analog Output Field Termination Assembly |
| System family | Honeywell TDC 3000 / TPS Process Manager I/O |
| Model code | MC-TAOX12 |
| Part number | 51304335-125 |
| FTA function | Analog output termination |
| System context | Process Manager / TPS I/O |
| Configuration control | Verify exact model-to-part-number pairing on the installed nameplate |
| Compatibility control | Confirm IOP, cable, terminals, output range and cabinet layout |
Honeywell MC-TAOX12 51304335-125 is an analog output field termination assembly that connects the compatible Process Manager output IOP to field loops; the exact part-number suffix controls the approved hardware arrangement.
The exact channel count for Honeywell MC-TAOX12 51304335-125 is not confirmed by the public Honeywell data reviewed for this page, so the installed nameplate, terminal map and project drawings must be used.
The terminal construction of Honeywell MC-TAOX12 51304335-125 must be confirmed from the installed assembly because it should not be inferred from another TAOX12 part number.
Redundancy for Honeywell MC-TAOX12 51304335-125 must be confirmed from the exact installed IOP and project configuration rather than assumed from a similar TAOX model.
Record the output range, field load, loop polarity, cable, grounding, terminal map, fail-state action and paired IOP before removing Honeywell MC-TAOX12 51304335-125.
Test every configured output from Honeywell MC-TAOX12 51304335-125 across the required range, confirm diagnostics and fail-state behavior, and verify redundant transfer when that function is installed.
Supply the complete Honeywell MC-TAOX12 51304335-125 model and part number, revision, IOP identity, terminal photographs, output configuration, quantity and destination.
Send the complete Honeywell model, part number, revision, quantity, destination and nameplate photo. Identification details will be verified before availability and lead time are confirmed.
Visit us
32D Guomao Building, No.388, Hubin South Road, Siming DistrictDisclaimer : Salesplcauto sells new and surplus products and develops channels for purchasing such products. This website has not been approved or recognized by any of the listed manufacturers or trademarks. Salesplcauto is not an authorized distributor, dealer, or representative of the products displayed on this website. All product names, trademarks, brands, and logos used on this website are the property of their respective owners. The description, explanation, or sale of products with these names, trademarks, brands, and logos is for identification purposes only and is not intended to indicate any association with or authorization from any rights holder.
Copyright @2026 SalesPlc Limited. Sitemap