MC-TAOX12 51304335-175
8-Output Redundant Analog Output FTA · Redundant Analog Output Field Termination Assembly
Lifecycle note: Use the unit nameplate and current Honeywell documentation as final references before approving a replacement.
Product Condition
Original New with One Year WarrantyParts Available
In Stock and Same Day ShippingDelivery Mode
Shipping via DHL Fedex or UPS etcEmail:
sales17@amikon.cnWhatsapp/Mob:
+86 153594082758-Output Redundant Analog Output FTA - Honeywell TDC 3000 / TPS Process Manager I/O
Honeywell MC-TAOX12 51304335-175 is an eight-output analog output field termination assembly for compatible redundant Process Manager I/O arrangements. It terminates field loops and interfaces them with the approved analog output processor hardware.
Honeywell planning information identifies the 51304335-175 variant with compression terminals, CE status and conformal coating. Its eight-channel redundant application differs from higher-density TAOY and nonredundant output arrangements.
Before installation, confirm the paired IOPs, redundancy configuration, output range, cable, terminal map, loop load, field power and failover behavior. Commission normal outputs, diagnostics and redundant transfer under the approved site procedure.
| Manufacturer | Honeywell |
|---|---|
| Complete model | MC-TAOX12 51304335-175 |
| Product type | Redundant Analog Output Field Termination Assembly |
| System family | Honeywell TDC 3000 / TPS Process Manager I/O |
| Model code | MC-TAOX12 |
| Part number | 51304335-175 |
| FTA function | Analog output termination |
| Output channels | 8 |
| Redundancy application | Supported with the approved redundant output arrangement |
| Terminal type | Compression |
| Part status | CE-compliant part number |
| Board protection | Conformally coated MC assembly |
Honeywell MC-TAOX12 51304335-175 is an analog output field termination assembly that connects the compatible Process Manager output IOP to field loops; the exact part-number suffix controls the approved hardware arrangement.
Honeywell MC-TAOX12 51304335-175 is documented as an eight-output field termination assembly, but the configured channel allocation and paired IOP must still be verified.
Honeywell MC-TAOX12 51304335-175 uses compression, so the matching field plug or compression wiring and cabinet layout must be retained.
Honeywell MC-TAOX12 51304335-175 is used with the approved redundant analog-output arrangement; confirm both output processors, cables, database settings and transfer behavior before replacement.
Record the output range, field load, loop polarity, cable, grounding, terminal map, fail-state action and paired IOP before removing Honeywell MC-TAOX12 51304335-175.
Test every configured output from Honeywell MC-TAOX12 51304335-175 across the required range, confirm diagnostics and fail-state behavior, and verify redundant transfer when that function is installed.
Supply the complete Honeywell MC-TAOX12 51304335-175 model and part number, revision, IOP identity, terminal photographs, output configuration, quantity and destination.
Send the complete Honeywell model, part number, revision, quantity, destination and nameplate photo. Identification details will be verified before availability and lead time are confirmed.
Visit us
32D Guomao Building, No.388, Hubin South Road, Siming DistrictDisclaimer : Salesplcauto sells new and surplus products and develops channels for purchasing such products. This website has not been approved or recognized by any of the listed manufacturers or trademarks. Salesplcauto is not an authorized distributor, dealer, or representative of the products displayed on this website. All product names, trademarks, brands, and logos used on this website are the property of their respective owners. The description, explanation, or sale of products with these names, trademarks, brands, and logos is for identification purposes only and is not intended to indicate any association with or authorization from any rights holder.
Copyright @2026 SalesPlc Limited. Sitemap
/ Blog
/ XML
/ Terms And Conditions
/ Privacy Policy