MC-TAOX52 51304335-275
8-Channel Analog Output FTA · Analog Output Field Termination Assembly
Lifecycle note: Use the unit nameplate and current Honeywell documentation as final references before approving a replacement.
Product Condition
Original New with One Year WarrantyParts Available
In Stock and Same Day ShippingDelivery Mode
Shipping via DHL Fedex or UPS etcEmail:
sales17@amikon.cnWhatsapp/Mob:
+86 153594082758-Channel Analog Output FTA - Honeywell TDC 3000 / TPS Process Manager I/O
Honeywell MC-TAOX52 51304335-275 is an eight-channel analog output field termination assembly for Process Manager I/O. It provides removable screw-terminal connections for analog field loops and the approved output IOP interface.
The 51304335-275 variant is identified as a CE-compliant, conformally coated assembly in the Size B format. The TAOX52 terminal construction is an important replacement distinction from compression-terminal TAOX12 hardware.
Verify the complete model, terminal plug, cable, paired IOP, output range, loop load, grounding and cabinet footprint before replacement. Test all eight loops, diagnostics and configured fail action before returning control to service.
| Manufacturer | Honeywell |
|---|---|
| Complete model | MC-TAOX52 51304335-275 |
| Product type | Analog Output Field Termination Assembly |
| System family | Honeywell TDC 3000 / TPS Process Manager I/O |
| Model code | MC-TAOX52 |
| Part number | 51304335-275 |
| FTA function | Analog output termination |
| Output channels | 8 |
| Terminal type | Removable screw terminals |
| Mounting size | Size B |
| Part status | CE-compliant part number |
| Board protection | Conformally coated MC assembly |
Honeywell MC-TAOX52 51304335-275 is an analog output field termination assembly that connects the compatible Process Manager output IOP to field loops; the exact part-number suffix controls the approved hardware arrangement.
Honeywell MC-TAOX52 51304335-275 is documented as an eight-output field termination assembly, but the configured channel allocation and paired IOP must still be verified.
Honeywell MC-TAOX52 51304335-275 uses removable screw terminals, so the matching field plug or compression wiring and cabinet layout must be retained.
Redundancy for Honeywell MC-TAOX52 51304335-275 must be confirmed from the exact installed IOP and project configuration rather than assumed from a similar TAOX model.
Record the output range, field load, loop polarity, cable, grounding, terminal map, fail-state action and paired IOP before removing Honeywell MC-TAOX52 51304335-275.
Test every configured output from Honeywell MC-TAOX52 51304335-275 across the required range, confirm diagnostics and fail-state behavior, and verify redundant transfer when that function is installed.
Supply the complete Honeywell MC-TAOX52 51304335-275 model and part number, revision, IOP identity, terminal photographs, output configuration, quantity and destination.
Send the complete Honeywell model, part number, revision, quantity, destination and nameplate photo. Identification details will be verified before availability and lead time are confirmed.
Visit us
32D Guomao Building, No.388, Hubin South Road, Siming DistrictDisclaimer : Salesplcauto sells new and surplus products and develops channels for purchasing such products. This website has not been approved or recognized by any of the listed manufacturers or trademarks. Salesplcauto is not an authorized distributor, dealer, or representative of the products displayed on this website. All product names, trademarks, brands, and logos used on this website are the property of their respective owners. The description, explanation, or sale of products with these names, trademarks, brands, and logos is for identification purposes only and is not intended to indicate any association with or authorization from any rights holder.