Bently Nevada 200150-09-CN 100 mV/g Case-Isolated Accelerometer
200150-09-CN
100 mV/g Case-Isolated Accelerometer · Case-isolated 100 mV/g accelerometer with option-09 mounting hardware; the exact CN country suffix requires nameplate verification.
Lifecycle note: Use the unit nameplate and current official documentation as final references before approving a replacement.
Product Condition
Original New with One Year WarrantyParts Available
In Stock and Same Day ShippingDelivery Mode
Shipping via DHL Fedex or UPS etcEmail:
sales17@amikon.cnWhatsapp/Mob:
+86 15359408275100 mV/g Case-Isolated Accelerometer · Bently Nevada 200150 Accelerometer
Bently Nevada 200150-09-CN is a case-isolated piezoelectric accelerometer for machinery casing-vibration measurements.
The 200150 family provides nominal 100 mV/g sensitivity, a +/-25 g measurement range and a 10 to 1000 Hz documented response, while option 09 identifies the 3/8-24 to 3/4 NPT mounting stud.
Because the current family datasheet does not explicitly map the complete CN suffix, verify the exact nameplate, country approval, mounting stud, connector, compatible monitor input, grounding and cable before replacement.
| Manufacturer | Bently Nevada |
|---|---|
| Model | 200150-09-CN |
| Base model | 200150 |
| Measured quantity | Machinery vibration acceleration |
| Sensitivity at 80 Hz | 10.2 mV/(m/s2), 100 mV/g, +/-12% |
| Measurement range | +/-245 m/s2 (+/-25 g) |
| Frequency range | 10 to 1000 Hz, +/-10% |
| Mounted resonant frequency | Greater than 20 kHz |
| Amplitude linearity | +/-2% from 1 to 10 g peak |
| Temperature range | -40 to +105 deg C |
| Electrical isolation | 600 Vrms |
| Mounting option 09 | 3/8-24 to 3/4 NPT stud, 1-1/4 in hex |
Bently Nevada 200150-09-CN measures machine-case acceleration and supplies a conditioned 100 mV/g signal to a compatible monitoring input.
Option 09 on Bently Nevada 200150-09-CN identifies a 3/8-24 to 3/4 NPT mounting stud with a 1-1/4-inch hex.
The 200150 sensor family used by Bently Nevada 200150-09-CN has a documented +/-25 g measurement range and 10 to 1000 Hz frequency response.
The exact CN suffix is not mapped in the current public family datasheet, so the approval and country execution must be confirmed from the label and current records.
Another 200150 option cannot directly replace Bently Nevada 200150-09-CN unless the stud, connector, electrical input, environmental rating and approval execution match.
Verify mounting torque, orientation, connector and cable, bias voltage, noise floor and controlled vibration response after installing Bently Nevada 200150-09-CN.
Provide the complete Bently Nevada 200150-09-CN label, mounting and connector photos, monitor input, country requirement, quantity and destination.
Send the complete 200150-09-CN catalog number, revision, quantity, destination and nameplate photo. Identification details will be checked before quotation.
Visit us
32D Guomao Building, No.388, Hubin South Road, Siming DistrictDisclaimer : Salesplcauto sells new and surplus products and develops channels for purchasing such products. This website has not been approved or recognized by any of the listed manufacturers or trademarks. Salesplcauto is not an authorized distributor, dealer, or representative of the products displayed on this website. All product names, trademarks, brands, and logos used on this website are the property of their respective owners. The description, explanation, or sale of products with these names, trademarks, brands, and logos is for identification purposes only and is not intended to indicate any association with or authorization from any rights holder.
Copyright @2026 SalesPlc Limited. Sitemap
/ Blog
/ XML
/ Terms And Conditions
/ Privacy Policy
Network Supported