FC-IO-0001
Safety Manager I/O Bus Module - I/O Bus Interface Module
Lifecycle note: Use the unit nameplate and current Honeywell documentation as final references before approving a replacement.
Product Condition
Original New with One Year WarrantyParts Available
In Stock and Same Day ShippingDelivery Mode
Shipping via DHL Fedex or UPS etcEmail:
sales17@amikon.cnWhatsapp/Mob:
+86 15359408275Safety Manager I/O Bus Module - Honeywell Safety Manager
Honeywell FC-IO-0001 is the IO-0001 bus module used within the Safety Manager chassis architecture. It provides the defined I/O-bus hardware interface between supported chassis assemblies.
The module requires 5 VDC at 35 mA with ripple below 50 mV peak-to-peak. Its mechanical allocation is 4 HP by 3U, allowing the correct slot and connector-key arrangement to be verified before installation.
Honeywell specifies A5 and A7 key positions for both module holes and the corresponding large chassis connector pins. These keys help prevent insertion into an incompatible position.
Before replacement, verify the complete FC-IO-0001 nameplate, chassis type, slot, A5/A7 keying, 5 V supply quality and the approved Safety Manager shutdown and restart procedure.
| Manufacturer | Honeywell |
|---|---|
| Complete model | FC-IO-0001 |
| Product type | I/O Bus Interface Module |
| System family | Honeywell Safety Manager |
| Type numbers | FS-IO-0001 and FC-IO-0001 |
| Power requirement | 5 VDC, 35 mA |
| Ripple limit | Less than 50 mV peak-to-peak |
| Space requirement | 4 HP, 3U |
| Connector key holes | A5 and A7 |
| Chassis connector pins | A5 and A7 |
| Approvals | CE, TUV, UL, CSA and FM |
Honeywell FC-IO-0001 is a i/o bus interface module for the Honeywell Safety Manager. It provides the IO-0001 bus interface used in the Safety Manager chassis.
Honeywell FC-IO-0001 provides the physical and electrical interface for the Safety Manager I/O bus in the supported chassis.
Honeywell FC-IO-0001 is installed in Safety Manager systems that use the IO-0001 bus architecture to connect control and I/O hardware.
Honeywell specifies 5 VDC at 35 mA, less than 50 mV peak-to-peak ripple, 4 HP by 3U space and A5/A7 connector keying.
Honeywell FC-IO-0001 must be installed in the correct keyed Safety Manager chassis position with compatible bus and processor hardware.
Before installing Honeywell FC-IO-0001, verify the complete model and revision, mounting arrangement, power, field wiring, grounding and approved Safety Manager configuration.
Commission Honeywell FC-IO-0001 under the approved Honeywell and site procedure. Prove its configured channels, diagnostics, communications and safety response before returning the system to service.
Do not substitute a similar suffix for Honeywell FC-IO-0001 until the hardware revision, electrical interface, companion assembly and Safety Manager release are confirmed compatible.
Provide the complete Honeywell FC-IO-0001 nameplate, version, serial number, companion hardware, Safety Manager release, quantity and destination.
Send the complete model, version, quantity, destination and nameplate photo. We will verify identification before confirming availability and lead time.
Visit us
32D Guomao Building, No.388, Hubin South Road, Siming DistrictDisclaimer : Salesplcauto sells new and surplus products and develops channels for purchasing such products. This website has not been approved or recognized by any of the listed manufacturers or trademarks. Salesplcauto is not an authorized distributor, dealer, or representative of the products displayed on this website. All product names, trademarks, brands, and logos used on this website are the property of their respective owners. The description, explanation, or sale of products with these names, trademarks, brands, and logos is for identification purposes only and is not intended to indicate any association with or authorization from any rights holder.