AO650
Analog Output Module · 3BHT300051R1 · Advant Controller 31
Lifecycle note: Confirm the exact AO650 identity, installation context and approved service procedure before replacement.
Product Condition
Original New with One Year WarrantyParts Available
In Stock and Same Day ShippingDelivery Mode
Shipping via DHL Fedex or UPS etcEmail:
sales17@amikon.cnWhatsapp/Mob:
+86 153 5940 8275Analog Output Module · Advant Controller 31
ABB AO650, order 3BHT300051R1, is an analog output module for the Advant Controller 31 platform. Match the model and order identity to the installed cabinet before replacement.
Integration depends on rack, terminal arrangement, project configuration and field signal requirements. Confirm these against approved drawings and the controller baseline.
For commissioning and MRO acceptance, retain nameplate, wiring, firmware and functional-test evidence and quarantine mismatched stock.
| Manufacturer | ABB |
|---|---|
| Model | AO650 |
| Order number | 3BHT300051R1 |
| Module type | Analog Output Module |
| System family | Advant Controller 31 |
| Application | Installed-base automation component |
| Signal / interface | 8-channel isolated analog outputs; 12-bit resolution |
| Channel or point count | 8 channels |
| Electrical range | 0-20 mA, 4-20 mA, ±20 mA; 0-5 V, 0-10 V, 1-5 V, ±10 V |
| Load / impedance | S600-configured load |
| Isolation / grounding | Each channel opto-isolated |
| Configuration / firmware | Verify project baseline |
| Hardware revision | Record nameplate revision |
| Procurement identity | AO650 / 3BHT300051R1 |
Distinguish the AO650 output stage from the upstream system supply. Preserve cabinet wiring and evaluate stored backup energy before intervention; verify loaded operation after an approved replacement.
Select the mode from the S600 project configuration and connected actuator requirements; confirm scaling before energizing the loop.
Compare commanded values, measured outputs and the configured engineering range across the approved test points.
Confirm the receiving circuit and current-loop load are compatible with the documented S600 configuration before commissioning.
Treat each opto-isolated channel independently and trace wiring and field faults without assuming a common channel failure.
Record signal mode, channel assignment, scaling, terminal unit, firmware baseline and project revision.
Freeze the control output, verify the replacement scaling and transfer control only after the measured output is stable.
State AO650, 3BHT300051R1, channel use, output mode, quantity, destination and nameplate evidence.
Inspect the board, connectors, revision and packaging, then run an approved channel check before installation.
Send the model, complete part number, quantity, destination and nameplate photo. We will verify identification details before confirming availability and lead time.
Manufacturer reference: ABB Operating manual - Trouble shooting, Advant Controller 31, 3HAC020738-001 Revision K, printed pages 62–64. Four-page file with Sales PLC cover, below 1 MB. Diagnostic limits are not general operating ratings.
Visit us
32D Guomao Building, No.388, Hubin South Road, Siming DistrictDisclaimer : Salesplcauto sells new and surplus products and develops channels for purchasing such products. This website has not been approved or recognized by any of the listed manufacturers or trademarks. Salesplcauto is not an authorized distributor, dealer, or representative of the products displayed on this website. All product names, trademarks, brands, and logos used on this website are the property of their respective owners. The description, explanation, or sale of products with these names, trademarks, brands, and logos is for identification purposes only and is not intended to indicate any association with or authorization from any rights holder.
Copyright @2026 SalesPlc Limited. Sitemap
/ Blog
/ XML
/ Terms And Conditions
/ Privacy Policy
Network Supported