TU846 3BSE022460R1
Redundant Communication Interface Module Termination Unit · Redundant communication-interface MTU for dual CI840 or CI840A modules and redundant S800 I/O.
Lifecycle note: Use the unit nameplate and current official documentation as final references before approving a replacement.
Product Condition
Original New with One Year WarrantyParts Available
In Stock and Same Day ShippingDelivery Mode
Shipping via DHL Fedex or UPS etcEmail:
sales17@amikon.cnWhatsapp/Mob:
+86 15359408275Redundant Communication Interface Module Termination Unit · ABB S800 I/O / System 800xA
ABB TU846 3BSE022460R1 is a redundant communication-interface Module Termination Unit for two CI840 or CI840A modules and redundant S800 I/O stations.
The MTU provides redundant PROFIBUS DP-V1, service, ModuleBus and optical connections while distributing the documented 24 VDC supply range to the communication-interface arrangement.
Because TU846 is not hot-swappable, isolate power before replacement and verify both CI840 or CI840A modules, PROFIBUS lines, station addressing, ModuleBus, optical expansion, DIN-rail orientation and controller configuration.
| Manufacturer | ABB |
|---|---|
| Type designation | TU846 |
| Article number | 3BSE022460R1 |
| Product type | Communication interface MTU |
| Supported interfaces | Two CI840 or CI840A communication interfaces |
| Fieldbus | PROFIBUS DP-V1 |
| Line redundancy | Yes |
| Module redundancy | Yes |
| Hot swap | No; disconnect power before replacement |
| Supply voltage | 24 VDC nominal; 19.2-30 VDC |
| ModuleBus length | 2.5 m maximum |
| Connections | Two PROFIBUS, two service-tool, two ModuleBus and optical port |
| Mounting | DIN rail, vertical or horizontal |
| Dimensions | 124 x 186 x 47 mm |
| Weight | 0.5 kg |
ABB TU846 3BSE022460R1 terminates two CI840 or CI840A communication interfaces for a redundant PROFIBUS DP-V1 and S800 I/O station.
ABB TU846 3BSE022460R1 supports line redundancy, communication-interface module redundancy and redundant I/O when the controller and station are engineered for those modes.
ABB TU846 3BSE022460R1 provides two PROFIBUS connectors, two service-tool connectors, two ModuleBus connectors and an optical ModuleBus interface.
ABB TU846 3BSE022460R1 is not documented for hot swap, so power must be isolated and the redundant station placed in the approved maintenance state before replacement.
ABB TU846 3BSE022460R1 uses a nominal 24 VDC supply with a documented 19.2 to 30 VDC operating range.
Commission ABB TU846 3BSE022460R1 by checking both CI840 or CI840A modules, PROFIBUS lines, ModuleBus and optical links, redundancy switching, diagnostics and controller I/O status.
Provide the full ABB TU846 3BSE022460R1 label, CI840 or CI840A revisions, station topology, wiring photos, quantity and destination.
Send the complete TU846 3BSE022460R1 catalog number, revision, quantity, destination and nameplate photo. Identification details will be checked before quotation.
Visit us
32D Guomao Building, No.388, Hubin South Road, Siming DistrictDisclaimer : Salesplcauto sells new and surplus products and develops channels for purchasing such products. This website has not been approved or recognized by any of the listed manufacturers or trademarks. Salesplcauto is not an authorized distributor, dealer, or representative of the products displayed on this website. All product names, trademarks, brands, and logos used on this website are the property of their respective owners. The description, explanation, or sale of products with these names, trademarks, brands, and logos is for identification purposes only and is not intended to indicate any association with or authorization from any rights holder.
Copyright @2026 SalesPlc Limited. Sitemap
/ Blog
/ XML
/ Terms And Conditions
/ Privacy Policy
Network Supported