100 mV/g Machinery Accelerometer · Case-isolated 100 mV/g accelerometer with 1/4-28 integral stud and multiple agency approvals.
Lifecycle note: Use the unit nameplate and current official documentation as final references before approving a replacement.
Product Condition
Original New with One Year WarrantyParts Available
In Stock and Same Day ShippingDelivery Mode
Shipping via DHL Fedex or UPS etcEmail:
sales17@amikon.cnWhatsapp/Mob:
+86 15359408275100 mV/g Machinery Accelerometer · Bently Nevada 330400 Accelerometer
Bently Nevada 330400-01-05 is a case-isolated acceleration transducer for critical machinery casing measurements and gear-mesh monitoring.
The sensor provides 100 mV/g sensitivity, a 50 g peak range and broad 10 Hz to 15 kHz response, with a 1/4-28 integral stud and multiple approvals.
Before replacement, verify the mounting surface and torque, connector and cable, constant-current input, frequency and acceleration range, grounding and installed approval requirements.
| Manufacturer | Bently Nevada |
|---|---|
| Model | 330400-01-05 |
| Sensitivity | 100 mV/g +/-5% |
| Acceleration range | 50 g peak |
| Amplitude linearity | +/-1% to 50 g peak |
| Frequency response | 10 Hz-15 kHz +/-3 dB |
| Precision band | 30 Hz-10 kHz +/-10% |
| Power | -24 VDC +/-0.5 VDC, 2 mA nominal |
| Output bias | -8.5 VDC +/-0.5 VDC |
| Grounding | Case isolated |
| Operating temperature | -55 to +121 deg C |
| Connector | 3-pin MIL-C-5015 |
| Mounting option 01 | 1/4-28 UNF integral stud |
| Approval option 05 | Multiple approvals |
| Protection | Sensor equivalent to IP68 |
Bently Nevada 330400-01-05 measures casing acceleration for critical machinery monitoring, including applications where high-frequency gear-mesh vibration is important.
Bently Nevada 330400-01-05 provides 100 mV/g nominal sensitivity with a 50 g peak acceleration range.
Bently Nevada 330400-01-05 is specified from 10 Hz to 15 kHz within 3 dB and from 30 Hz to 10 kHz within 10 percent.
Bently Nevada 330400-01-05 uses a 1/4-28 UNF integral stud and option 05 for multiple agency approvals.
A 330425 cannot directly replace Bently Nevada 330400-01-05 because its sensitivity and acceleration range differ even though the mechanical family is similar.
Prepare a rigid flat mounting surface, apply the specified torque, verify connector and cable condition, confirm bias and grounding, and check dynamic response for Bently Nevada 330400-01-05.
Provide the complete Bently Nevada 330400-01-05 code, mounting and cable details, monitor input, approval requirement, quantity and destination.
Send the complete 330400-01-05 catalog number, revision, quantity, destination and nameplate photo. Identification details will be checked before quotation.
Visit us
32D Guomao Building, No.388, Hubin South Road, Siming DistrictDisclaimer : Salesplcauto sells new and surplus products and develops channels for purchasing such products. This website has not been approved or recognized by any of the listed manufacturers or trademarks. Salesplcauto is not an authorized distributor, dealer, or representative of the products displayed on this website. All product names, trademarks, brands, and logos used on this website are the property of their respective owners. The description, explanation, or sale of products with these names, trademarks, brands, and logos is for identification purposes only and is not intended to indicate any association with or authorization from any rights holder.
Copyright @2026 SalesPlc Limited. Sitemap
/ Blog
/ XML
/ Terms And Conditions
/ Privacy Policy
Network Supported