EH0*A
EH0*A is the Yokogawa Style A output isolator for a 1–5 V signal path. Check EH0*A against the MHC signal-conditioner nest, field load and existing terminal arrangement.
Scope note: EH0*A is supplied as 1–5 v output isolator card; terminal hardware, cables and system engineering are selected or verified separately.
Product Condition
Original New with One Year WarrantyParts Available
In Stock and Same Day ShippingDelivery Mode
Shipping via DHL Fedex or UPS etcEmail:
sales1@amikon.cnWhatsapp/Mob:
+86 181501176851–5 V Output Isolator Card
EH0*A is the Yokogawa Style A output isolator for a 1–5 V signal path. Check EH0*A against the MHC signal-conditioner nest, field load and existing terminal arrangement.
Application guidance: Isolated 1–5 V output-loop maintenance. Compatible MHC signal-conditioner assemblies. Like-for-like replacement with output load verified.
Ordering note: Reproduce EH0*A exactly and confirm the installed hardware, terminal arrangement, project release and site requirements.
| Manufacturer | Yokogawa Electric Corporation |
|---|---|
| Full part number | EH0*A |
| Function | Voltage output isolation |
| Input | 1–5 V DC |
| Output | 1–5 V DC, one output |
| Load resistance | 2 kohms minimum |
| Supply | 24 V DC ±10% |
| Style | A |
| Nest | MHC; not MHM |
| Accuracy | ±0.1% of span (EH0 family) |
Before EH0*A replacement, retain the approved configuration and follow the applicable host maintenance and commissioning procedure. Verify the complete hardware and software combination before migration.
EH0*A is the voltage-output isolator for a 1–5 V DC input and one 1–5 V DC output.
EH0*A is listed for MHC signal-conditioner nests; Yokogawa excludes EH0 output cards from MHM nests.
Check the receiving device and parallel connections for EH0*A against the documented minimum output load of 2 kohms.
EH0*A provides voltage output. Yokogawa lists EA0 for 4–20 mA output, so confirm the actual field signal before replacement.
For EH0*A, compare the nest terminals, polarity and receiving-device connections with the applicable drawing, then perform a documented loop check.
For EH0*A replacement, confirm style and assembly compatibility with the installed system before selecting another revision.
Include EH0*A, the complete tag, MHC nest model, receiving-device load and quantity so the supply can be matched to the existing loop.
Send the exact EH0*A nameplate, quantity, installed Yokogawa system, terminal hardware, destination and clear photos. Availability, condition and compatibility will be confirmed before quotation.
Verify the cited document revision and its applicability to the complete model, style and installed assembly. Family-level documentation does not establish interchangeability for an unlisted suffix.
Visit us
32D Guomao Building, No.388, Hubin South Road, Siming DistrictDisclaimer : Salesplcauto sells new and surplus products and develops channels for purchasing such products. This website has not been approved or recognized by any of the listed manufacturers or trademarks. Salesplcauto is not an authorized distributor, dealer, or representative of the products displayed on this website. All product names, trademarks, brands, and logos used on this website are the property of their respective owners. The description, explanation, or sale of products with these names, trademarks, brands, and logos is for identification purposes only and is not intended to indicate any association with or authorization from any rights holder.