ET5*B
ET5*B is documented as a thermocouple-input signal-conditioning card. Match ET5*B to the host assembly, thermocouple type and reference-junction arrangement before commissioning.
Scope note: ET5*B is supplied as thermocouple input signal conditioning card; terminal hardware, cables and system engineering are selected or verified separately.
Product Condition
Original New with One Year WarrantyParts Available
In Stock and Same Day ShippingDelivery Mode
Shipping via DHL Fedex or UPS etcEmail:
sales1@amikon.cnWhatsapp/Mob:
+86 18150117685Thermocouple Input Signal Conditioning Card
ET5*B is documented as a thermocouple-input signal-conditioning card. Match ET5*B to the host assembly, thermocouple type and reference-junction arrangement before commissioning.
Application guidance: Thermocouple signal conditioning. Like-for-like maintenance of the documented ET5*B installation. Spare and migration review using the full installed-system record.
Ordering note: Reproduce ET5*B exactly and confirm the installed hardware, terminal arrangement, project release and site requirements.
| Manufacturer | Yokogawa Electric Corporation |
|---|---|
| Full part number | ET5*B |
| Input | Thermocouple |
| Verified application | YS150/YS170 /A02 |
| Configuration | SC MAINT in the documented YS installation |
| Variant check | Confirm host and any /YS marking |
Before ET5*B replacement, retain the approved configuration and follow the applicable host maintenance and commissioning procedure. Verify the complete hardware and software combination before migration.
ET5*B is identified as the /A02 thermocouple option for YS150/YS170.
ET5*B uses B06 T/C Type for thermocouple selection in the documented SC MAINT menu.
Correct ET5*B temperature measurement depends on the applicable host's reference-junction arrangement.
Do not infer that equivalence from ET5*B alone; confirm the complete label and host installation.
Record ET5*B thermocouple type, units, zero, span and burnout settings.
Use appropriate thermocouple simulation and verify ET5*B readings and sensor-failure response against the intended configuration.
Provide ET5*B label photographs, host model, thermocouple type, required range and any additional assembly markings.
Send the exact ET5*B nameplate, quantity, installed Yokogawa system, terminal hardware, destination and clear photos. Availability, condition and compatibility will be confirmed before quotation.
Verify the cited document revision and its applicability to the complete model, style and installed assembly. Family-level documentation does not establish interchangeability for an unlisted suffix.
Visit us
32D Guomao Building, No.388, Hubin South Road, Siming DistrictDisclaimer : Salesplcauto sells new and surplus products and develops channels for purchasing such products. This website has not been approved or recognized by any of the listed manufacturers or trademarks. Salesplcauto is not an authorized distributor, dealer, or representative of the products displayed on this website. All product names, trademarks, brands, and logos used on this website are the property of their respective owners. The description, explanation, or sale of products with these names, trademarks, brands, and logos is for identification purposes only and is not intended to indicate any association with or authorization from any rights holder.
Copyright @2026 SalesPlc Limited. Sitemap
/ Blog
/ XML
/ Terms And Conditions
/ Privacy Policy
Network Supported