+86 15359408275P1 5 A Genset Controller · Woodward easYgen-2000 Series
Woodward 8440-2080 easYgen-2300 is the easYgen-2300 P1 package with 5 A current-transformer inputs. The controller integrates generator and mains measurement, breaker sequencing, synchronization, protection, engine start/stop logic and power-management functions for compatible generating systems.
Woodward 8440-2080 easYgen-2300 supports automatic, manual and stop modes, mains-parallel and multiple-unit island operation, AMF, standby, load-dependent start/stop, import/export functions and load/var sharing for up to 16 gensets when configured with the required system components.
Official specification 37548 lists eight configurable discrete inputs, six configurable outputs, three analog inputs, two analog outputs, one CAN interface, RS-485 Modbus RTU and a service connection for ToolKit configuration. The controller records 300 events with a battery-backed real-time clock.
Before commissioning or replacing Woodward 8440-2080 easYgen-2300, confirm the P1 package, 5 A CT circuits, voltage sensing, breaker arrangement, CAN/RS-485 topology, terminal mapping, firmware and ToolKit parameter file. Protection and synchronization tests must precede automatic operation.
| Manufacturer | Woodward |
|---|---|
| Model | 8440-2080 easYgen-2300 |
| Product type | Generator Set Control and Power Management Unit |
| System family | Woodward easYgen-2000 Series |
| Package | easYgen-2300 P1 |
| Rated CT secondary | 5 A |
| Discrete I/O | 8 configurable inputs; 6 configurable outputs |
| Analog I/O | 3 configurable inputs; 2 configurable outputs |
| CAN interfaces | 1 |
| Serial interface | RS-485 Modbus RTU slave |
| Parallel operation | Multiple-unit island operation up to 16 gensets |
| Event recorder | 300 entries with real-time clock |
Use the installed-unit nameplate, current Woodward documentation and approved site engineering records as the final references.
Woodward 8440-2080 easYgen-2300 is the P1 package with 5 A current-transformer inputs. The official ordering table distinguishes it from P2 and from other easYgen-2000 models, so the part number and CT secondary rating must be retained.
Woodward 8440-2080 easYgen-2300 supports compatible single-unit mains-parallel, multiple-unit island, AMF, standby, load-dependent start/stop and load/var-sharing applications. Breaker hardware, sensing, communications and project logic determine the functions actually enabled.
Official specification 37548 lists eight configurable discrete inputs, six configurable outputs, three configurable analog inputs and two configurable analog outputs for Woodward 8440-2080 easYgen-2300. External expansion requires compatible CANopen hardware and configuration.
Woodward 8440-2080 easYgen-2300 provides one CAN interface, an RS-485 Modbus RTU slave interface and a service connection for ToolKit configuration. Confirm protocol roles, node addresses, baud rates, termination and the required service cable before connection.
Verify supply, protective earth, 5 A CT secondary wiring, generator and mains voltage sensing, phase rotation, breaker outputs, engine I/O, CAN termination and RS-485 biasing before energizing Woodward 8440-2080 easYgen-2300.
Use the correct ToolKit file for Woodward 8440-2080 easYgen-2300, validate measurement scaling and phase relationships, then test engine sequencing, breaker interlocks, synchronization, protections, alarms and communications. Complete controlled tests before selecting automatic or parallel modes.
An XT migration requires terminal, sensing, communication, display, firmware and application review. Although Woodward provides migration guidance, Woodward 8440-2080 easYgen-2300 settings and wiring should not be copied into an XT controller without an engineered conversion plan.
Specify part number 8440-2080, P1 package, 5 A CT rating, revision, serial number, firmware and ToolKit configuration. Include generator and mains ratings, breaker arrangement, communication topology and required approvals to validate the replacement configuration.
Woodward product specification 37548 lists Woodward 8440-2080 easYgen-2300 and its major functions, I/O, communications and ordering code. The applicable easYgen-2000 technical manual and project ToolKit file provide detailed wiring and parameter instructions.
Send the complete model, part number, revision, quantity, destination and nameplate photo. We will verify identification details before confirming availability and lead time.
Visit us
32D Guomao Building, No.388, Hubin South Road, Siming DistrictDisclaimer : Salesplcauto sells new and surplus products and develops channels for purchasing such products. This website has not been approved or recognized by any of the listed manufacturers or trademarks. Salesplcauto is not an authorized distributor, dealer, or representative of the products displayed on this website. All product names, trademarks, brands, and logos used on this website are the property of their respective owners. The description, explanation, or sale of products with these names, trademarks, brands, and logos is for identification purposes only and is not intended to indicate any association with or authorization from any rights holder.