Woodward 8440-2082 easYgen-3200XT-P1 Genset Controller for Up to 32 Generator Sets
8440-2082 easYgen-3200XT-P1
Genset Controller for Up to 32 Generator Sets · Generator Set Control and Power Management Unit for Woodward easYgen-3000XT Series
Lifecycle note: Use the unit nameplate and current Woodward documentation as final references before approving a replacement.
Product Condition
Original New with One Year WarrantyParts Available
In Stock and Same Day ShippingDelivery Mode
Shipping via DHL Fedex or UPS etcEmail:
sales17@amikon.cnWhatsapp/Mob:
+86 15359408275Genset Controller for Up to 32 Generator Sets · Woodward easYgen-3000XT Series
Woodward 8440-2082 easYgen-3200XT-P1 is the front-panel easYgen-3200XT P1 genset controller with an integrated color display and softkey operation. The controller combines generator and mains measurement, breaker control, synchronization, protection, engine sequencing and power-management functions.
Woodward 8440-2082 easYgen-3200XT-P1 supports automatic, manual, stop and test modes, AMF and standby operation, import/export control, load-dependent start and stop, and load/var sharing for systems of up to 32 generating sets when engineered with compatible communications and switchgear.
The official specification lists 12 discrete alarm inputs, up to 12 configurable outputs, three configurable analog inputs, two analog outputs, two CAN interfaces, Ethernet Modbus TCP, USB service and RS-485 Modbus RTU. External I/O can be expanded through the supported CANopen architecture.
For installation or migration, confirm the P1 application, CT and voltage-sensing circuits, breaker logic, CAN and Ethernet topology, terminal mapping, firmware, ToolKit configuration, access levels and protection settings. Woodward 8440-2082 easYgen-3200XT-P1 is not commissioned safely by copying an unrelated parameter set.
| Manufacturer | Woodward |
|---|---|
| Model | 8440-2082 easYgen-3200XT-P1 |
| Product type | Generator Set Control and Power Management Unit |
| System family | Woodward easYgen-3000XT Series |
| Package | easYgen-3200XT P1, front-panel mounting with display |
| Parallel operation | Up to 32 gensets |
| Configurable discrete inputs | 12 (10 configurable alarm inputs) |
| Configurable discrete outputs | Maximum 12 |
| Analog I/O | 3 configurable inputs; 2 configurable outputs |
| CAN interfaces | 2 FlexCAN interfaces |
| Network/service interfaces | Ethernet Modbus TCP, USB serial, RS-485 Modbus RTU |
| Operating temperature | −20 to +70 °C |
Use the installed-unit nameplate, current Woodward documentation and approved site engineering records as the final references.
Woodward 8440-2082 easYgen-3200XT-P1 is the front-panel P1 package with an integrated color display. Official specification 37582 distinguishes it from the back-mounted 3100XT and the low-temperature 3200XT-P1-LT part-number variant.
Woodward 8440-2082 easYgen-3200XT-P1 supports single and multiple genset systems, mains-parallel operation, AMF, standby, import/export control and load/var sharing for up to 32 units. The actual application depends on engineered switchgear and communications.
The official specification lists 12 discrete alarm inputs, up to 12 configurable outputs, three configurable analog inputs and two configurable analog outputs for Woodward 8440-2082 easYgen-3200XT-P1. External CANopen I/O requires supported modules and project configuration.
Woodward 8440-2082 easYgen-3200XT-P1 provides two FlexCAN interfaces, Ethernet Modbus TCP, USB serial service and RS-485 Modbus RTU. CAN channel functions, node addresses, Ethernet settings and protocol roles must be selected in the approved ToolKit configuration.
Verify panel cutout and fastening, supply, protective earth, generator and mains voltage circuits, CT secondary wiring, breaker outputs, engine I/O, CAN termination and Ethernet segregation before energizing Woodward 8440-2082 easYgen-3200XT-P1.
Load or create the correct ToolKit file for Woodward 8440-2082 easYgen-3200XT-P1, then verify measurement scaling, phase rotation, breaker logic, engine sequencing, protections, communications and access levels. Perform controlled functional tests before enabling automatic or parallel operation.
Woodward documents note similar panel dimensions and retained easYgen communication concepts, but terminal mapping and service interfaces differ. Compare sensing ranges, CT wiring, terminal assignments, USB service, CAN/Ethernet setup, firmware and application logic before migration.
Provide part number 8440-2082, revision, serial number, firmware, ToolKit application file, genset and mains voltage, CT ratios, breaker arrangement, communication topology and required approvals. Confirm that P1 with display—not LT or back-mounted hardware—is required.
Woodward product specification 37582 identifies Woodward 8440-2082 easYgen-3200XT-P1 and summarizes functions, I/O, communications and approvals. Technical manual 37574 and the exact configuration file provide installation, parameter and commissioning instructions.
Send the complete model, part number, revision, quantity, destination and nameplate photo. We will verify identification details before confirming availability and lead time.
Visit us
32D Guomao Building, No.388, Hubin South Road, Siming DistrictDisclaimer : Salesplcauto sells new and surplus products and develops channels for purchasing such products. This website has not been approved or recognized by any of the listed manufacturers or trademarks. Salesplcauto is not an authorized distributor, dealer, or representative of the products displayed on this website. All product names, trademarks, brands, and logos used on this website are the property of their respective owners. The description, explanation, or sale of products with these names, trademarks, brands, and logos is for identification purposes only and is not intended to indicate any association with or authorization from any rights holder.
Copyright @2026 SalesPlc Limited. Sitemap
/ Blog
/ XML
/ Terms And Conditions
/ Privacy Policy
Network Supported