8440-2085 easYgen-3500XT
easYgen-3500XT-P1 Genset Controller · Complex Paralleling Genset Controller for Woodward easYgen-3000XT Series
Lifecycle note: Use the unit nameplate and current Woodward documentation as final references before approving a replacement.
Product Condition
Original New with One Year WarrantyParts Available
In Stock and Same Day ShippingDelivery Mode
Shipping via DHL Fedex or UPS etcEmail:
sales17@amikon.cnWhatsapp/Mob:
+86 15359408275easYgen-3500XT-P1 Genset Controller · Woodward easYgen-3000XT Series
Woodward 8440-2085 easYgen-3500XT is the easYgen-3500XT-P1 front-panel genset controller with an integrated display. Woodward product specification 37583 identifies this exact part number for complex generator-set paralleling and power-management applications.
Woodward 8440-2085 easYgen-3500XT measures three-phase generator and mains voltage up to 690 Vac, three-phase generator current and single-phase mains or ground current. The 1 A or 5 A current inputs are selected in software and must match the installed current transformers and protection scaling.
The P1 configuration supports single- and multiple-generator operation, mains-parallel control, automatic mains-failure and standby applications, critical-mode operation, and synchronization of generator and mains circuit breakers. The easYgen-3500XT platform can coordinate complex systems with compatible Woodward breaker controllers.
Commissioning Woodward 8440-2085 easYgen-3500XT requires verification of voltage and CT circuits, phase rotation, breaker feedback, protection settings, CAN and Ethernet architecture, application configuration, firmware and saved project data. The exact P1 package must not be confused with P2 or low-temperature variants.
| Manufacturer | Woodward |
|---|---|
| Model | 8440-2085 easYgen-3500XT |
| Product type | Complex Paralleling Genset Controller |
| System family | Woodward easYgen-3000XT Series |
| Exact configuration | easYgen-3500XT-P1, front-panel mounting with display |
| Generator voltage | Three-phase, up to 690 Vac |
| Generator current | Three-phase, 1 A or 5 A software selectable |
| Mains voltage | Three-phase, up to 690 Vac |
| Mains or ground current | Single-phase, 1 A or 5 A software selectable |
| Busbar voltage | Single-phase for P1 package |
| Complex paralleling | Single or multiple units, mains parallel and AMF applications |
| Fast breaker transition | Open and closed transition control, less than 100 ms as specified |
| Interfaces | Ethernet Modbus TCP, USB, RS-485 Modbus RTU and configurable CAN interfaces |
Use the installed-unit nameplate, current Woodward documentation and approved site engineering records as the final references.
Woodward 8440-2085 easYgen-3500XT is the front-panel easYgen-3500XT-P1 controller with an integrated display. Product specification 37583 distinguishes this P1 part number from cabinet-back P1, P2 and low-temperature easYgen-3000XT configurations.
Woodward 8440-2085 easYgen-3500XT supports compatible single- and multiple-generator systems, mains-parallel operation, automatic mains failure, standby operation and critical modes. The configured breaker logic and plant architecture must match the approved application design.
Woodward 8440-2085 easYgen-3500XT measures three-phase generator and mains voltage up to 690 Vac. Generator current is three-phase, while mains or ground current is single-phase; 1 A or 5 A inputs are software selectable.
The P1 package of Woodward 8440-2085 easYgen-3500XT uses a single-phase busbar-voltage measurement. Do not transfer P2 wiring assumptions; verify the exact terminal plan, potential-transformer arrangement and application configuration in manual 37580.
Woodward 8440-2085 easYgen-3500XT provides Ethernet Modbus TCP, USB, RS-485 Modbus RTU and configurable CAN interfaces in the easYgen-3000XT platform. Port settings, device roles, termination and network architecture require project-specific commissioning.
Commission Woodward 8440-2085 easYgen-3500XT by verifying sensing polarity and phase rotation, CT ratios, breaker feedback, protection thresholds, synchronization, load sharing, alarms, network communication and emergency shutdown before enabling automatic or parallel operation.
No direct substitution should be assumed. Woodward 8440-2085 easYgen-3500XT is the P1 front-panel model; P2, cabinet-back and low-temperature variants differ. Compare hardware package, terminals, sensing, display, firmware, licenses and configuration before migration.
Specify Woodward 8440-2085 easYgen-3500XT with the complete part number, P1 package, revision, serial number, firmware, project file, CT secondary rating, system voltage, breaker arrangement, network design and required approvals to verify the replacement.
Woodward product specification 37583 lists Woodward 8440-2085 easYgen-3500XT and its verified features. Technical manual 37580 provides P1 installation and configuration instructions; application-specific drawings and the saved project remain essential commissioning references.
Send the complete model, part number, revision, quantity, destination and nameplate photo. We will verify identification details before confirming availability and lead time.
Visit us
32D Guomao Building, No.388, Hubin South Road, Siming DistrictDisclaimer : Salesplcauto sells new and surplus products and develops channels for purchasing such products. This website has not been approved or recognized by any of the listed manufacturers or trademarks. Salesplcauto is not an authorized distributor, dealer, or representative of the products displayed on this website. All product names, trademarks, brands, and logos used on this website are the property of their respective owners. The description, explanation, or sale of products with these names, trademarks, brands, and logos is for identification purposes only and is not intended to indicate any association with or authorization from any rights holder.