9907-167
505E Digital Governor for Extraction/Admission Steam Turbines · Extraction/Admission Steam Turbine Governor for Woodward 505E Control Series
Lifecycle note: Use the unit nameplate and current Woodward documentation as final references before approving a replacement.
Product Condition
Original New with One Year WarrantyParts Available
In Stock and Same Day ShippingDelivery Mode
Shipping via DHL Fedex or UPS etcEmail:
sales17@amikon.cnWhatsapp/Mob:
+86 15359408275505E Digital Governor for Extraction/Admission Steam Turbines · Woodward 505E Control Series
Woodward 9907-167 is the 18–32 Vdc low-voltage version of the 505E Digital Governor for steam turbines with controlled extraction and/or admission pressure. Woodward manual 85018V1 identifies this exact part-number option.
Woodward 9907-167 coordinates turbine speed or load with extraction and admission pressure control in engineered generator or mechanical-drive applications. The configured valve arrangement and process-pressure strategy determine the approved operating logic.
The 505E platform integrates configurable control, sequencing, protection interfaces, local operation and plant-system communication. Correct commissioning depends on validated speed sensors, pressure transmitters, actuators, permissives, alarms and trip circuits.
When replacing Woodward 9907-167, retain the 18–32 Vdc supply option and restore only the verified application configuration. Confirm revision, grounding, terminal assignments, actuator ranges, valve curves and extraction/admission settings before operation.
| Manufacturer | Woodward |
|---|---|
| Model | 9907-167 |
| Product type | Extraction/Admission Steam Turbine Governor |
| System family | Woodward 505E Control Series |
| Power input | 18–32 Vdc |
| Turbine service | Controlled extraction and/or admission pressure |
| Controller family | 505E Digital Governor |
| Application modes | Generator or mechanical-drive steam turbine |
| Configuration | Field programmable for the engineered turbine application |
| Operator functions | Local configuration and operating interface |
| Plant integration | Hardwired signals and documented communications |
| Replacement check | LVDC supply, revision, I/O, actuator and configuration file |
Use the installed-unit nameplate, current Woodward documentation and approved site engineering records as the final references.
Woodward 9907-167 is the 18–32 Vdc version of the 505E Digital Governor for steam turbines requiring controlled extraction and/or admission pressure together with speed or load control.
Woodward 9907-167 requires an 18–32 Vdc source. Check polarity, voltage under load, protective earth, circuit protection, terminal assignment and the complete nameplate before energizing it.
Woodward 9907-167 is applied to compatible extraction or admission steam turbines in generator or mechanical-drive service. Confirm valve geometry, actuator direction and process-pressure requirements.
Both are 505E controllers, but Woodward 9907-167 uses 18–32 Vdc while 9907-165 uses 180–264 Vac. Power-input versions must not be interchanged without engineering verification.
Verify Woodward 9907-167 speed sensing, pressure inputs, actuator outputs, generator or process signals, permissives, alarms, trips and communication circuits against the approved turbine documentation.
Configure Woodward 9907-167 only from the approved turbine application records, including valve arrangement, extraction/admission priorities, pressure and speed tuning, actuator ranges, sequencing and protection settings.
Before installation, verify Woodward 9907-167 LVDC polarity and capacity, grounding, shielding, terminal wiring, environmental conditions, actuator circuits, pressure transmitters and independent overspeed protection.
Do not assume direct replacement. Match Woodward 9907-167 power option, hardware revision, terminals, firmware, approvals and complete application configuration before changing any installed controller.
Provide the complete Woodward 9907-167 nameplate, revision, serial number, 18–32 Vdc supply, turbine and valve arrangement, process requirements, configuration backup, certifications, quantity and destination.
Send the complete model, part number, revision, quantity, destination and nameplate photo. We will verify identification details before confirming availability and lead time.
Visit us
32D Guomao Building, No.388, Hubin South Road, Siming DistrictDisclaimer : Salesplcauto sells new and surplus products and develops channels for purchasing such products. This website has not been approved or recognized by any of the listed manufacturers or trademarks. Salesplcauto is not an authorized distributor, dealer, or representative of the products displayed on this website. All product names, trademarks, brands, and logos used on this website are the property of their respective owners. The description, explanation, or sale of products with these names, trademarks, brands, and logos is for identification purposes only and is not intended to indicate any association with or authorization from any rights holder.
Copyright @2026 SalesPlc Limited. Sitemap
/ Blog
/ XML
/ Terms And Conditions
/ Privacy Policy
Network Supported