1747-L532 PLC SLC 5/03 16K Controller Processor
1747-L532
SLC 5/03 processor with 16K words of program memory, RS-232 and DH-485 communications, and support for up to three local chassis. Confirm the exact installed configuration and revision before replacement.
Scope note: Supplied as a model-specific industrial component; system engineering, accessories and site acceptance are verified separately.
Product Condition
Original New with One Year WarrantyParts Available
In Stock and Same Day ShippingDelivery Mode
Shipping via DHL Fedex or UPS etcEmail:
sales1@amikon.cnWhatsapp/Mob:
+86 1815011768516K-word modular controller processor for SLC 500 SLC 5/03
This modular SLC 500 processor executes the control program and manages local I/O across an SLC 5/03 system with as many as three chassis and 30 I/O slots.
Its built-in interfaces are RS-232 and DH-485 rather than native Ethernet, so replacement or migration requires a review of the existing program, network, chassis arrangement and battery-backed memory.
Ordering note: Verify the complete model, installed system, revision and current manufacturer documentation before purchase or installation.
| Manufacturer / family | PLC SLC 500 SLC 5/03 |
|---|---|
| Program memory | 16K words |
| Maximum discrete I/O | 4096 inputs and 4096 outputs |
| Maximum local system | Three chassis and 30 I/O slots |
| Instruction set | 107 programming instructions |
| Typical scan time | 1 ms/K for a representative ladder program |
| Communications | Channel 0 RS-232 and Channel 1 DH-485 |
| Backplane current | 500 mA at 5 VDC and 175 mA at 24 VDC |
Compatibility depends on the complete ordering code, installed hardware, wiring and approved engineering data.
The controller provides 16K words of program memory.
The processor includes one RS-232 channel and one DH-485 channel.
The local system can use as many as three chassis containing a total of 30 I/O slots.
The documented typical scan rate is 1 ms/K, with an XIC execution time of 0.44 microseconds.
No drop-in catalog substitute is identified because Rockwell classifies the migration as an engineering replacement.
Send the complete 1747-L532 model, quantity, installed system, destination and clear label photos. Availability and condition will be confirmed before quotation.
Visit us
32D Guomao Building, No.388, Hubin South Road, Siming DistrictDisclaimer : Salesplcauto sells new and surplus products and develops channels for purchasing such products. This website has not been approved or recognized by any of the listed manufacturers or trademarks. Salesplcauto is not an authorized distributor, dealer, or representative of the products displayed on this website. All product names, trademarks, brands, and logos used on this website are the property of their respective owners. The description, explanation, or sale of products with these names, trademarks, brands, and logos is for identification purposes only and is not intended to indicate any association with or authorization from any rights holder.