SDI01
32-Channel 24 VDC Digital Input Module · Thirty-two-channel digital input module for Toshiba Integrated Controller V Series model 2000/3000 systems, accepting 24 VDC field signals with online replacement support.
Lifecycle note: Use the unit nameplate and current Toshiba documentation as final references before approving a replacement.
Product Condition
Original New with One Year WarrantyParts Available
In Stock and Same Day ShippingDelivery Mode
Shipping via DHL Fedex or UPS etcEmail:
sales17@amikon.cnWhatsapp/Mob:
+86 1535940827532-Channel 24 VDC Digital Input Module · Toshiba Integrated Controller V Series Model 2000/3000
Toshiba SDI01 is a 32-channel digital input module for the Integrated Controller V Series model 2000/3000 serial I/O architecture. Each channel accepts a documented 24 VDC, 5 mA field input.
The SDI01 channels are not insulated from one another, and Toshiba lists a 50 mA 24 V current requirement. Online replacement is supported within the approved controller procedure and installed configuration.
Before replacement, record the base position, terminal assignments, common wiring, field-supply polarity and application channel map. Confirm the replacement SDI01 against the current Toshiba controller documentation.
| Manufacturer | Toshiba |
|---|---|
| Model | SDI01 |
| Product type | Digital input module |
| System family | Integrated Controller V Series model 2000/3000 |
| Input channels | 32 |
| Input rating | 24 VDC, 5 mA |
| Inter-channel insulation | Not insulated |
| Online swap | Supported |
| 24 V current | 50 mA |
| Replacement control | Match base, terminal wiring, channel assignment and controller configuration |
Toshiba SDI01 receives 32 discrete 24 VDC field signals for a compatible Integrated Controller V Series model 2000 or model 3000 serial I/O station.
Toshiba SDI01 uses 24 VDC digital inputs rated at 5 mA per documented channel, so field-device voltage and common wiring must match the module specification.
Toshiba SDI01 does not provide inter-channel insulation, so the installed common arrangement and field-supply references must be verified before wiring or replacement.
Toshiba lists online swap support for SDI01, but the controller procedure, station status, field hazards and site change-control rules must authorize the operation.
Toshiba SDI01 commissioning should confirm the slot or station assignment, channel map, input polarity, common wiring, diagnostic state and application response.
A digital output module cannot substitute for Toshiba SDI01 because SDI01 is configured to receive 32 field input signals rather than drive output loads.
Provide the Toshiba SDI01 nameplate, controller model, base and slot, terminal arrangement, field voltage, channel use, quantity, condition requirement and destination.
Send the complete model, revision, quantity, destination and nameplate photo so the exact hardware identity can be checked.
Visit us
32D Guomao Building, No.388, Hubin South Road, Siming DistrictDisclaimer : Salesplcauto sells new and surplus products and develops channels for purchasing such products. This website has not been approved or recognized by any of the listed manufacturers or trademarks. Salesplcauto is not an authorized distributor, dealer, or representative of the products displayed on this website. All product names, trademarks, brands, and logos used on this website are the property of their respective owners. The description, explanation, or sale of products with these names, trademarks, brands, and logos is for identification purposes only and is not intended to indicate any association with or authorization from any rights holder.
Copyright @2026 SalesPlc Limited. Sitemap
/ Blog
/ XML
/ Terms And Conditions
/ Privacy Policy