NIMF02
Multi-Function Controller Termination Module
Lifecycle note: NIMF02 is installed-base automation hardware. Confirm the complete configuration before replacement.
Product Condition
Original New with One Year WarrantyParts Available
In Stock and Same Day ShippingDelivery Mode
Shipping via DHL Fedex or UPS etcEmail:
info@amikon.cnWhatsapp/Mob:
+86 18020776786Multi-Function Controller Termination Module · INFI 90 / Network 90
ABB NIMF02 is a Multi-Function Controller Termination Module for INFI 90 / Network 90. It supports installed control and maintenance strategies where the exact module identity and approved configuration must remain traceable.
Engineering review should use the published technical identifiers together with the installed revision, rack or termination arrangement, connector mapping, power rails, communication or signal configuration and current site drawings. Similar Bailey or Symphony designations must not be treated as interchangeable without an application-level comparison.
For commissioning and MRO control, isolate the affected equipment, record the pre-change state, inspect connectors and labels, reproduce only approved settings, complete functional tests and update the asset record. Procurement should require clear nameplate photographs, condition disclosure and unit traceability.
| Manufacturer | ABB / Bailey Controls |
|---|---|
| Model | NIMF02 |
| Module type | Multi-Function Controller Termination Module |
| System family | INFI 90 / Network 90 |
| Supply | 24 VDC |
| Maximum current | 160 mA including 10 mA LED |
| Communication ports | 2 RS-232-C ports |
| Station link | 1 serial link for control stations |
| Controller compatibility | IMMFC03 / IMMFC04 / IMMFC05 |
| Related station hardware | NICS01 / NIDS01 |
| PVC cable rating | 80 deg C at 300 V; UL CL2 |
| Non-PVC cable rating | 90 deg C at 300 V; UL PLTC |
| Mounting | Single termination mounting-unit slot |
| Operating temperature | 0 to 70 deg C |
NIMF02 is installed-base automation hardware. Confirm the complete system, power, interface and revision details before replacement or migration.
Document device, wiring, baud parameters and DCE/DTE role for each port.
Verify the installed IMMFC03, IMMFC04 or IMMFC05 and its revision.
It provides the serial interface for the associated control-station arrangement.
Use 160 mA maximum including the 10 mA indicator load.
PVC is 80 deg C at 300 V; non-PVC PLTC is 90 deg C at 300 V.
Verify both serial channels, station link, indicator and stable current.
Port damage and bent contacts may not appear in a faceplate image.
Update controller association, port map, cables, revision, serial and test results.
Send the model, quantity, destination and nameplate photo. We will verify identification details before confirming availability and lead time.
The model-relevant ABB manufacturer extract is linked in the Technical Data section. File size is below 1 MB; verify the exact installed hardware and configuration before use.
Visit us
32D Guomao Building, No.388, Hubin South Road, Siming DistrictDisclaimer : Salesplcauto sells new and surplus products and develops channels for purchasing such products. This website has not been approved or recognized by any of the listed manufacturers or trademarks. Salesplcauto is not an authorized distributor, dealer, or representative of the products displayed on this website. All product names, trademarks, brands, and logos used on this website are the property of their respective owners. The description, explanation, or sale of products with these names, trademarks, brands, and logos is for identification purposes only and is not intended to indicate any association with or authorization from any rights holder.
Copyright @2026 SalesPlc Limited. Sitemap
/ Blog
/ XML
/ Terms And Conditions
/ Privacy Policy
Network Supported