3008
Main Processor Module · 32-bit Motorola MPC860 · 50 MHz · 16 MB DRAM · Triple Modular Redundancy
Lifecycle note: Triconex 3008 is used in safety-related Tricon systems. Confirm chassis, system version, firmware and project configuration before replacement.
Product Condition
Original New with One Year WarrantyParts Available
In Stock and Same Day ShippingDelivery Mode
Shipping via DHL Fedex or UPS etcEmail:
info@amikon.cnWhatsapp/Mob:
+86 18020776786Main Processor Module · Tricon Safety Systems
Triconex 3008 is a Main Processor Module for Tricon Safety Systems, supporting safety-related control, system diagnostics and maintenance activities in Tricon v9.6 and later installations. The exact model, hardware revision and approved system configuration should remain traceable throughout replacement and lifecycle support.
Key engineering identifiers include a 32-bit Motorola MPC860 processor, 50 MHz clock speed, 16 MB non-battery-backed DRAM, 32 KB battery-backed SRAM, 6 MB Flash PROM and a 25 Mb/s TriBus communication rate. System integrators should also verify chassis compatibility, firmware, I/O communication interfaces and the applicable TriStation project before installation.
For commissioning and MRO procurement, confirm the complete part number, nameplate, module condition, quantity, destination and revision restrictions. Follow the approved isolation and test procedure, record diagnostic results and system response, and ensure the supplied module matches the installed safety-system architecture before returning the equipment to service.
| Manufacturer | Triconex / Schneider Electric |
|---|---|
| Model | 3008 |
| Processor | 32-bit Motorola MPC860 |
| Clock speed | 50 MHz |
| DRAM | 16 MB non-battery-backed |
| SRAM | 32 KB battery-backed |
| Flash PROM | 6 MB |
| TriBus data rate | 25 Mb/s |
| Diagnostic serial port | 1 × optically isolated RS-232 |
| Real-time clock accuracy | ±2 seconds/day |
| Architecture | Triple Modular Redundancy (3 channels) |
Tricon is a legacy Triconex automation platform. Confirm the complete installed configuration before replacement or migration.
Check the module nameplate for the complete 3008 model, hardware revision and firmware information. Compare these details with the installed processor, chassis and system documentation before ordering.
The 3008 is a main processor module for Tricon safety systems. It executes the configured application as one channel of the Triple Modular Redundancy architecture.
A Tricon system uses three main processor channels. Each channel independently processes its part of the application and exchanges information through the TriBus so the system can compare results and diagnose differences.
No. Similar model numbers must not be assumed interchangeable. Confirm the complete part number, system release, chassis, processor population, hardware revision and firmware before replacement.
The 3008 is identified for Tricon version 9.6 and later systems. Compatibility must still be verified against the exact installed system and project documentation.
Confirm the chassis model, existing processor arrangement, system release, firmware, TriStation project, approved backups and the plant replacement procedure. Safety-related work must follow qualified engineering and management-of-change controls.
Availability must be checked against current warehouse records. Provide the required quantity and clear nameplate photographs so model, revision, condition and dispatch timing can be confirmed.
Record the PASS, FAULT, ACTIVE, MAINT1/2, COM TX/RX and I/O TX/RX indicator states before taking action. Review the TriStation diagnostic and event records for processor health, TriBus voting, I/O-bus and communication-bus errors, clock and SOE synchronization, then compare the status of all three main processors. Isolate the failed channel and follow the approved site procedure before hot replacement or return to service.
Confirm that all three main processors are correctly installed and seated, then check the PASS, FAULT, ACTIVE, MAINT1/2 and COM/I/O indicators. Verify TriBus communication, I/O and communication-bus operation, time and SOE synchronization, redundancy health, diagnostics and application execution. Return the system to service only after the approved functional and safety validation is complete.
Send the model, complete part number, quantity, destination and nameplate photo. We will verify identification details before confirming availability and lead time.
Official PDF extract: Official Triconex Product Specifications — Model 3008. File size is below 1 MB; verify the exact installed hardware and configuration before use.
Visit us
32D Guomao Building, No.388, Hubin South Road, Siming DistrictDisclaimer : Salesplcauto sells new and surplus products and develops channels for purchasing such products. This website has not been approved or recognized by any of the listed manufacturers or trademarks. Salesplcauto is not an authorized distributor, dealer, or representative of the products displayed on this website. All product names, trademarks, brands, and logos used on this website are the property of their respective owners. The description, explanation, or sale of products with these names, trademarks, brands, and logos is for identification purposes only and is not intended to indicate any association with or authorization from any rights holder.
Copyright @2026 SalesPlc Limited. Sitemap
/ Blog
/ XML
/ Terms And Conditions
/ Privacy Policy