ItemNO:
469-P5-HI-A1Payment:
T/TProductOrigin:
United StatesLeadTime:
Subject to verificationProduct Condition
Original New with One Year WarrantyParts Available
In Stock and Same Day ShippingDelivery Mode
Shipping via DHL Fedex or UPS etcEmail:
sales8@amikon.cnWhatsapp/Mob:
+86 18030235313Base-Panel Motor Management Relay · Multilin 469 Motor Protection System
469-P5-HI-A1 is a concise but complete order string. It specifies the 5 A CT input, wide-range HI control power and 0–1 mA analog-output choice, while retaining the base front-panel configuration.
The buyer check differs from the E-H version: confirm that the site actually requires the base panel and does not rely on enhanced-display, Ethernet or conformal-coating options that are absent from this code.
| Manufacturer | GE Vernova Multilin |
|---|---|
| Exact model | 469-P5-HI-A1 |
| P5 option | 5 A phase CT secondaries |
| HI option | 90–300 V DC or 70–265 V AC, 48–62 Hz control power |
| A1 option | 0–1 mA analog-output range |
| Display configuration | Base front panel; no E or T suffix in this order string |
| Environmental option | No H suffix specified |
| Thermal inputs | 12 RTD inputs in the 469 family |
| Digital outputs | Six electromechanical Form C output relays |
| Serial interfaces | Front RS232 and two RS485 ports using Modbus RTU |
| Replacement caution | Do not silently upgrade the option string without checking form, function and site approval |
For a base 469 installation, compare exact spare availability with GE Vernova's 8 Series Retrofit Kit. The migration must preserve protection philosophy and field I/O, not only the physical panel opening.
It specifies 5 A phase CT inputs, the HI control-power range and 0–1 mA analog outputs on the base 469 configuration.
No. The E-H model adds an enhanced front panel and harsh-environment conformal coating; those suffixes are absent here.
The official ordering guide associates 10BaseT Ethernet with the T option. This order string has no T suffix.
The brochure lists one front RS232 port, two RS485 ports and Modbus RTU half-duplex operation.
Follow site CT safety procedures, short CT circuits as required, verify ratio and polarity, and compare terminal assignments with the correct manual.
A1 is the 0–1 mA option. A receiving loop designed for 4–20 mA must not be assumed compatible without an engineered signal-interface change.
Save settings, logic, setpoint reports, event records and communications information, and document every terminal and field wire.
Send the model, complete part number, quantity, destination and nameplate photo. We will verify identification details before confirming availability and lead time.
Technical information is based on GE Vernova Multilin 469 Official Brochure. Final suitability must be verified against the exact installed unit and official documentation.
Email us
Reply within one working dayVisit us
32D Guomao Building, No.388, Hubin South Road, Siming DistrictDisclaimer : Featuredplc sells new and surplus products and develops channels for purchasing such products. This website has not been approved or recognized by any of the listed manufacturers or trademarks. Featuredplc is not an authorized distributor, dealer, or representative of the products displayed on this website. All product names, trademarks, brands, and logos used on this website are the property of their respective owners. The description, explanation, or sale of products with these names, trademarks, brands, and logos is for identification purposes only and is not intended to indicate any association with or authorization from any rights holder.
Copyright @2024 SalesPlc Limited. Sitemap
/ Blog
/ XML
/ Terms And Conditions
/ Privacy Policy
Network Supported