SR750-P5-G5-S5-HI-A20-R
Feeder Management Relay · Multilin 750 feeder protection · 5 A phase, ground and sensitive-ground inputs · eight 4–20 mA outputs
Lifecycle note: Legacy 750/760 platform — confirm order code, firmware and installed communications before replacement.
Product Condition
Original New with One Year WarrantyParts Available
In Stock and Same Day ShippingDelivery Mode
Shipping via DHL Fedex or UPS etcEmail:
sales8@amikon.cnWhatsapp/Mob:
+86 18030235313Feeder Management Relay · Multilin 750
The Multilin 750 provides feeder protection, metering, monitoring and control in one relay platform.
This order code is configured for 5 A phase, ground and sensitive-ground inputs, the HI power-supply range, eight 4–20 mA analog outputs and a red breaker-closed indication.
| Manufacturer | GE Multilin |
|---|---|
| Model / order code | SR750-P5-G5-S5-HI-A20-R |
| Product family | 750/760 Feeder Protection System |
| Phase current inputs | P5 · 5 A |
| Zero-sequence ground input | G5 · 5 A |
| Sensitive-ground input | S5 · 5 A |
| Power supply | HI · 88–300 VDC or 70–265 VAC, 48–62 Hz |
| Analog outputs | A20 · eight 4–20 mA outputs |
| Breaker status LED | R · red breaker-closed LED |
Legacy 750/760 platform — confirm order code, firmware and installed communications before replacement.
GE SR750-P5-G5-S5-HI-A20-R Feeder Management Relay is a Feeder Management Relay in the Multilin 750 product family. The Multilin 750 provides feeder protection, metering, monitoring and control in one relay platform.
The principal identification points are Phase Input: P5 · 5 A; Ground Input: G5 / S5 · 5 A; Power Supply: HI Range; Analog Output: 8 × 4–20 mA. Confirm these values against the exact unit nameplate and official documentation.
Typical applications include Distribution-feeder protection, Feeder metering and automation, Multilin 750 installed-base replacement. The installed system design remains the final suitability reference.
Verify All three 5 A CT input circuits, 4–20 mA receiving equipment, Firmware and communication requirements. Also provide the required quantity, destination and a clear nameplate photo.
Yes. Hardware revision, option code, electrical rating, connector arrangement and system firmware can affect compatibility, even when two units have a similar front label.
A direct substitution should not be assumed. Compare the full model, revision, electrical data, interfaces, wiring and application requirements before approving an alternative.
Legacy 750/760 platform — confirm order code, firmware and installed communications before replacement.
Refer to GE Vernova 750/760 Official Brochure. The exact unit nameplate and manufacturer documentation remain the final configuration references.
Send the model, complete part number, quantity, destination and nameplate photo. We will verify identification details before confirming availability and lead time.
Technical information is based on GE Vernova 750/760 Official Brochure. Final suitability must be verified against the exact installed unit and official documentation.
Visit us
32D Guomao Building, No.388, Hubin South Road, Siming DistrictDisclaimer : Salesplcauto sells new and surplus products and develops channels for purchasing such products. This website has not been approved or recognized by any of the listed manufacturers or trademarks. Salesplcauto is not an authorized distributor, dealer, or representative of the products displayed on this website. All product names, trademarks, brands, and logos used on this website are the property of their respective owners. The description, explanation, or sale of products with these names, trademarks, brands, and logos is for identification purposes only and is not intended to indicate any association with or authorization from any rights holder.