TU831V1
Extended Module Termination Unit · 3BSE013235R1
Lifecycle note: ABB TU831V1 is installed-base Extended Module Termination Unit. Confirm terminal style, hardware revision, mounting, termination and controller configuration before replacement.
Product Condition
Original New with One Year WarrantyParts Available
In Stock and Same Day ShippingDelivery Mode
Shipping via DHL Fedex or UPS etcEmail:
sales17@amikon.cnWhatsapp/Mob:
+86 153 5940 8275Extended Module Termination Unit · S800 I/O
ABB TU831V1, article 3BSE013235R1, is a Extended Module Termination Unit for S800 I/O. This selected hardware identity must remain traceable to the installed system, cabinet drawings and maintenance records.
Engineering review should compare Rated isolation: 250 V; Signal terminals: 2 x 8; Mounting: DIN rail; Terminal style: Extended MTU; Module interface: S800 I/O. Confirm these values against the field circuit, termination, power arrangement and controller configuration before commissioning.
For replacement and MRO procurement, isolate the affected equipment, record the pre-change state, verify the complete article number and revision, preserve approved settings and complete documented functional tests before return to service.
| Manufacturer | ABB |
|---|---|
| Model | TU831V1 |
| Order number | 3BSE013235R1 |
| Module type | Extended Module Termination Unit |
| System family | S800 I/O |
| Rated isolation | 250 V |
| Signal terminals | 2 x 8 |
| Mounting | DIN rail |
| Terminal style | Extended MTU |
| Module interface | S800 I/O |
| Field wiring | Pluggable terminals |
| Application | High-voltage isolated I/O |
| Orientation | Vertical module mounting |
| Identity | 3BSE013235R1 |
S800 I/O is a legacy ABB automation platform. Confirm the complete installed configuration before replacement or migration.
Use the published thresholds: -3 to +5 V for state 0 and +15 to +30 V for state 1. Values in the undefined region require field-circuit investigation before commissioning.
Adjust the 2–32 ms delay only after reviewing contact bounce, pulse duration and process response. Record the approved value for every affected input group.
It defines the separation expected between field inputs and internal electronics. Inspect the ECZ base and insulation condition; perform only site-approved dielectric or insulation tests.
Reuse is acceptable only after terminal numbering, common conductors, polarity and conductor condition match the approved drawings and the replacement nameplate.
Allow for the documented maximum consumption of 0.2 A and maximum dissipation of 4.5 W, then include the module in the cabinet power and thermal calculation.
Typical causes include marginal field voltage, loose terminals, contact bounce, induced noise or an incorrect delay. Measure the signal at the ECZ terminal before replacing hardware.
Check 3BSE013235R1, connector and housing condition, terminal cleanliness, label traceability and channel response using a controlled 24 VDC test source.
Purchase against the full FPR number. 3BSE013235R1 is the 24 VDC selection; FPR3316101R0036 and FPR3316101R0034 identify different supply variants.
Send the model, complete part number, quantity, destination and nameplate photo. We will verify identification details before confirming availability and lead time.
Visit us
32D Guomao Building, No.388, Hubin South Road, Siming DistrictDisclaimer : Salesplcauto sells new and surplus products and develops channels for purchasing such products. This website has not been approved or recognized by any of the listed manufacturers or trademarks. Salesplcauto is not an authorized distributor, dealer, or representative of the products displayed on this website. All product names, trademarks, brands, and logos used on this website are the property of their respective owners. The description, explanation, or sale of products with these names, trademarks, brands, and logos is for identification purposes only and is not intended to indicate any association with or authorization from any rights holder.
Copyright @2026 SalesPlc Limited. Sitemap
/ Blog
/ XML
/ Terms And Conditions
/ Privacy Policy
Network Supported