PLC 1794-OE4XT Four-Channel Extended-Temperature Analog Output Module
1794-OE4XT
Four-Channel Extended-Temperature Analog Output Module · Four-channel analog output module for voltage or current field devices in extended-temperature installations.
Lifecycle note: Use the unit nameplate and current official documentation as final references before approving a replacement.
Product Condition
Original New with One Year WarrantyParts Available
In Stock and Same Day ShippingDelivery Mode
Shipping via DHL Fedex or UPS etcEmail:
sales17@amikon.cnWhatsapp/Mob:
+86 15359408275Four-Channel Extended-Temperature Analog Output Module · Distributed I/O Hardware
1794-OE4XT is a four-channel extended-temperature analog output module that drives voltage or current field devices from a compatible distributed I/O adapter and terminal base.
Its channels support ±10 V or 0-20 mA output ranges with 12-bit-plus-sign resolution and a 16-bit two’s-complement data format.
Before replacement, verify the adapter, terminal base, keyswitch position, configured range for each channel, field supply, load resistance, scaling and safe output-state behavior.
| Model | 1794-OE4XT |
|---|---|
| Output channels | 4 single-ended, non-isolated |
| Voltage range | ±10 V |
| Current range | 0-20 mA |
| Resolution | 12 bits plus sign |
| Data format | 16-bit two’s complement, left justified |
| Voltage load | 3 mA maximum |
| Current load | 15-750 ohms |
| External supply | 24 VDC nominal |
| Supply range | 19.2-31.2 VDC |
| Keyswitch position | 4 |
| Terminal bases | 1794-TB2, TB3, TB3S, TB3T, TB3TS or TBN |
| Operating temperature | -20 to +70 °C |
1794-OE4XT operates as four-channel extended-temperature analog output module within Distributed I/O Hardware, and its installed role must be confirmed from the host system configuration and field wiring.
1794-OE4XT must be matched by the complete catalog number, channel or interface configuration, electrical ratings, connector arrangement and the limits listed in the technical table.
Before replacing 1794-OE4XT, record the slot or mounting position, wiring and terminal assignments, communication or channel settings, scaling, alarms, firmware or parameter data and the host configuration.
A similar-looking unit should not replace 1794-OE4XT until the electrical function, revision, interfaces, channel count, mounting, software support and application approval are confirmed.
Installation of 1794-OE4XT requires inspection of the connector and nameplate, correct supply polarity and rating, secure mounting, approved grounding and shielding, and controlled functional testing.
1794-OE4XT should be commissioned under the approved site procedure by checking diagnostics, each configured signal or network path, safe-state behavior and the response of the connected equipment.
An inquiry for 1794-OE4XT should include the full nameplate and revision, host equipment, installed configuration, connector or wiring photographs, required quantity, condition requirement and destination.
Send the complete 1794-OE4XT catalog number, revision, quantity, destination and nameplate photo. Identification details will be checked before quotation.
Visit us
32D Guomao Building, No.388, Hubin South Road, Siming DistrictDisclaimer : Salesplcauto sells new and surplus products and develops channels for purchasing such products. This website has not been approved or recognized by any of the listed manufacturers or trademarks. Salesplcauto is not an authorized distributor, dealer, or representative of the products displayed on this website. All product names, trademarks, brands, and logos used on this website are the property of their respective owners. The description, explanation, or sale of products with these names, trademarks, brands, and logos is for identification purposes only and is not intended to indicate any association with or authorization from any rights holder.
Copyright @2026 SalesPlc Limited. Sitemap
/ Blog
/ XML
/ Terms And Conditions
/ Privacy Policy
Network Supported