Vibro-Meter 200-560-000-111 IOC4T Input/Output Signal Interface Card
200-560-000-111
IOC4T Input/Output Signal Interface Card · Input/Output Card for MPC4 Machinery Protection Card for Vibro-Meter VM600 Machinery Protection System
Lifecycle note: Use the unit nameplate and current Vibro-Meter documentation as final references before approving a replacement.
Product Condition
Original New with One Year WarrantyParts Available
In Stock and Same Day ShippingDelivery Mode
Shipping via DHL Fedex or UPS etcEmail:
sales17@amikon.cnWhatsapp/Mob:
+86 15359408275IOC4T Input/Output Signal Interface Card · Vibro-Meter VM600 Machinery Protection System
Vibro-Meter 200-560-000-111 is an IOC4T input/output card for the VM600 machinery protection system. Installed at the rear of a VM600 rack, it forms the signal-interface half of an MPC4/IOC4T card pair and connects directly to the rack backplane.
Vibro-Meter 200-560-000-111 routes four dynamic measurement signals and two speed or phase-reference signals between field wiring and the paired MPC4 processing card. Three 16-contact screw-terminal connectors provide 48 terminals for measurement-chain inputs, relay contacts, discrete controls, analog outputs and buffered raw signals.
Four analog outputs on Vibro-Meter 200-560-000-111 can be selected individually for 0 to 10 V or 4 to 20 mA operation. The card also includes four software-assignable local relays and can place 32 alarm signals on the VM600 rack bus for optional RLC16 or IRC4 relay cards.
The complete 200-560-000-111 identifier must be retained when planning a replacement. Confirm the corresponding MPC4 PNR, rack type, slot position, channel wiring, jumper selections, relay logic, output impedance and MPSx configuration before installing or commissioning this IOC4T card.
| Manufacturer | Vibro-Meter |
|---|---|
| Model | 200-560-000-111 |
| Product type | Input/Output Card for MPC4 Machinery Protection Card |
| System family | Vibro-Meter VM600 Machinery Protection System |
| MPC4 signal inputs | 4 dynamic inputs and 2 speed or phase-reference inputs |
| Terminal connections | Three 16-contact screw-terminal connectors (48 terminals total) |
| Analog outputs | 4 outputs; 0 to 10 V or 4 to 20 mA, individually jumper-selectable |
| Local alarm relays | 4 software-assignable relays |
| Rack alarm interface | 32 programmable open-collector outputs for IRC4 or RLC16 cards |
| Rack position | Rear of the VM600 rack, directly behind the paired MPC4 card |
| Card supply | VM600 rack supply: +5 VDC and ±12 VDC |
| Exact order check | Use the complete 200-560-000-111 PNR and verify the paired MPC4 version, output impedance, relay wiring and rack database before replacement. |
Use the installed-unit nameplate, current Vibro-Meter documentation and approved site engineering records as the final references.
Vibro-Meter 200-560-000-111 is an IOC4T input/output signal-interface card that operates with a corresponding MPC4 machinery protection card in a VM600 rack.
Vibro-Meter 200-560-000-111 mounts at the rear of an ABE04x or ABE056 VM600 rack, directly behind its paired MPC4 card and connected to the backplane.
Vibro-Meter 200-560-000-111 interfaces four dynamic measurement channels and two speed or phase-reference channels. The installed MPC4 database defines scaling, processing and alarm behavior.
Vibro-Meter 200-560-000-111 provides four analog outputs, one per dynamic channel. Each output is jumper-selectable for a calibrated 0 to 10 V or 4 to 20 mA signal.
Vibro-Meter 200-560-000-111 contains four software-assignable local relays and passes 32 programmable alarm signals to the VM600 rack bus for optional RLC16 or IRC4 relay cards.
Vibro-Meter 200-560-000-111 provides discrete inputs for alarm reset, danger bypass and trip multiply. Their active behavior depends on the paired MPC4 configuration and site wiring.
Another IOC4T suffix should not replace Vibro-Meter 200-560-000-111 until hardware revision, output impedance, circuit version, coating, MPC4 pairing and rack approval have been checked.
Before installing Vibro-Meter 200-560-000-111, verify the rear slot, MPC4 PNR, connector wiring, jumper positions, relay loads, analog-output mode, rack supply and saved MPSx database.
Provide the complete Vibro-Meter 200-560-000-111 PNR, hardware revision, paired MPC4 PNR, VM600 rack and slot, channel wiring, output mode, relay requirements, quantity and destination.
Send the complete model, part number, revision, quantity, destination and nameplate photo. We will verify identification details before confirming availability and lead time.
Visit us
32D Guomao Building, No.388, Hubin South Road, Siming DistrictDisclaimer : Salesplcauto sells new and surplus products and develops channels for purchasing such products. This website has not been approved or recognized by any of the listed manufacturers or trademarks. Salesplcauto is not an authorized distributor, dealer, or representative of the products displayed on this website. All product names, trademarks, brands, and logos used on this website are the property of their respective owners. The description, explanation, or sale of products with these names, trademarks, brands, and logos is for identification purposes only and is not intended to indicate any association with or authorization from any rights holder.