Vibro-Meter 620-022-000-11X IOCR2 Input/Output and Communications Interface Card
620-022-000-11X
IOCR2 Input/Output and Communications Interface Card · Rack Controller Interface Card for Vibro-Meter VM600 System
Lifecycle note: Use the unit nameplate and current Vibro-Meter documentation as final references before approving a replacement.
Product Condition
Original New with One Year WarrantyParts Available
In Stock and Same Day ShippingDelivery Mode
Shipping via DHL Fedex or UPS etcEmail:
sales17@amikon.cnWhatsapp/Mob:
+86 15359408275IOCR2 Input/Output and Communications Interface Card · Vibro-Meter VM600 System
Vibro-Meter 620-022-000-11X is an IOCR2 input/output and communications interface card for a VM600 CPUR2 rack-controller installation.
The IOCR2 provides the external interface side of the CPUR2/IOCR2 card pair and must be matched to the associated CPUR2 processing card and rack configuration.
Official documentation requires CPUR2 to be used with IOCR2 and states that this card-pair generation does not provide the redundant behavior of the earlier CPUR/IOCR architecture.
Preserve the complete 620-022-000-11X identification, connector assignment, fieldbus wiring, CPUR2 firmware and VM600 database when planning replacement or commissioning.
| Manufacturer | Vibro-Meter |
|---|---|
| Model | 620-022-000-11X |
| Product type | Rack Controller Interface Card |
| System family | Vibro-Meter VM600 System |
| Designation | IOCR2 |
| Ordering format | 620-022-000-VVV |
| Controller pair | CPUR2 + IOCR2 |
| Card-pair redundancy | Not supported |
| Fieldbus interfaces | Up to 2 |
| Fieldbus protocols | Modbus TCP and PROFIBUS DP |
| Modbus capacity | Up to 131072 registers/words and 131072 coils/bits total |
| PROFIBUS DP data | Up to 244 input bytes and 244 output bytes per interface |
| System Ethernet interfaces | 2 |
| System Ethernet standard | 10/100/1000BASE-T(X) |
| Maximum system Ethernet rate | 1000 Mbps (1 Gbps) |
| Ethernet fieldbus interfaces | 2 × 10/100BASE-TX |
| Maximum fieldbus Ethernet rate | 100 Mbps |
| Serial fieldbus interfaces | 2 × RS-485, 2-wire or 4-wire |
| Maximum serial rate | 12 Mbps |
| Supply voltage | 5 VDC |
| IOCR2 consumption | 1 W |
| Pair power consumption | 7.5 W max.; ≤6 W typical |
| Operating temperature | 0 to 65°C |
| Storage temperature | −20 to 85°C |
| Operating humidity | 0 to 90% RH, non-condensing |
| Maximum altitude | 2000 m |
| Dimensions (H × W × D) | 262 × 20 × 125 mm |
| Approximate weight | 0.25 kg |
Use the installed-unit nameplate, current Vibro-Meter documentation and approved site engineering records as the final references.
Vibro-Meter 620-022-000-11X is an IOCR2 input/output and communications interface card used with a CPUR2 processing card in a VM600 rack-controller pair.
Vibro-Meter 620-022-000-11X is paired with a CPUR2 processing card. Match both complete PNRs, rack locations, connectors, firmware and system database before replacement.
Vibro-Meter 620-022-000-11X is the interface member of a CPUR2/IOCR2 pair and is not documented as a stand-alone rack controller. Verify the associated CPUR2.
A CPUR2/IOCR2 pair using Vibro-Meter 620-022-000-11X does not support the card-pair redundancy documented for the earlier CPUR and IOCR generation.
For Vibro-Meter 620-022-000-11X, verify the paired CPUR2 fieldbus setup, network addressing, cable termination, connector allocation and approved VM600 engineering database.
Vibro-Meter 620-022-000-11X is the IOCR2 interface used with CPUR2, while the earlier IOCR works with CPUR and can participate in redundant CPUR/IOCR pairs.
Before installing Vibro-Meter 620-022-000-11X, isolate the rack, follow electrostatic precautions, inspect rear connectors and card guides, and confirm its documented slot and CPUR2 pairing.
Another IOCx card should not replace Vibro-Meter 620-022-000-11X until the CPUx generation, interfaces, redundancy design, firmware, rack compatibility and database are confirmed.
Provide the complete Vibro-Meter 620-022-000-11X PNR, revision, serial number, paired CPUR2 PNR, rack model, firmware, fieldbus configuration, quantity and destination.
Send the complete model, part number, revision, quantity, destination and nameplate photo. We will verify identification details before confirming availability and lead time.
Visit us
32D Guomao Building, No.388, Hubin South Road, Siming DistrictDisclaimer : Salesplcauto sells new and surplus products and develops channels for purchasing such products. This website has not been approved or recognized by any of the listed manufacturers or trademarks. Salesplcauto is not an authorized distributor, dealer, or representative of the products displayed on this website. All product names, trademarks, brands, and logos used on this website are the property of their respective owners. The description, explanation, or sale of products with these names, trademarks, brands, and logos is for identification purposes only and is not intended to indicate any association with or authorization from any rights holder.
Copyright @2026 SalesPlc Limited. Sitemap
/ Blog
/ XML
/ Terms And Conditions
/ Privacy Policy
Network Supported