489-P5-HI-A20
Generator Protection, Monitoring and Management Relay · Multifunction relay for generator protection, metering, monitoring and controlled maintenance support.
Lifecycle note: Use the unit nameplate and current official documentation as final references before approving a replacement.
Product Condition
Original New with One Year WarrantyParts Available
In Stock and Same Day ShippingDelivery Mode
Shipping via DHL Fedex or UPS etcEmail:
sales17@amikon.cnWhatsapp/Mob:
+86 15359408275Generator Protection, Monitoring and Management Relay · GE Multilin 489 Generator Management Relay
GE Multilin 489-P5-HI-A20 is a multifunction generator management relay used for protection, metering, monitoring and diagnostic support in a configured generator application.
The P5, HI and A20 suffixes form part of the exact hardware order code, so CT inputs, control power, output options and the installed wiring must be verified from the nameplate and project records.
Before replacement, preserve the settings file and event data, then confirm instrument transformers, trip and alarm contacts, voltage inputs, communications, firmware and approved protection study.
| Manufacturer | GE Multilin |
|---|---|
| Model | 489-P5-HI-A20 |
| Product family | 489 Generator Management Relay |
| Primary application | Generator protection and management |
| Protection scope | Electrical protection, monitoring and diagnostics |
| Configuration check | CT ratings, voltage inputs, trip logic and setpoints |
| Communication check | Installed ports, protocol and address |
| Replacement check | Complete suffix, firmware, wiring and settings file |
GE Multilin 489-P5-HI-A20 combines generator electrical protection, metering, event information and control outputs according to the configured protection scheme.
The suffixes in GE Multilin 489-P5-HI-A20 identify ordered hardware choices, so CT inputs, control power and output configuration must match the installed relay.
Back up protection setpoints, CT and VT ratios, logic, output assignments, communications, passwords and disturbance or event configuration from GE Multilin 489-P5-HI-A20.
Another 489 relay should not replace GE Multilin 489-P5-HI-A20 until suffixes, firmware, terminal wiring, I/O options and the approved settings file are confirmed.
Verify CT circuits, voltage inputs, control power, trip and alarm contacts, communications and grounding before energizing GE Multilin 489-P5-HI-A20.
Commission GE Multilin 489-P5-HI-A20 using approved secondary-injection, logic, output-contact and communication tests coordinated with the generator protection study.
Provide the full GE Multilin 489-P5-HI-A20 nameplate, firmware, settings backup, terminal and rear-panel photos, quantity, condition and destination.
Send the complete 489-P5-HI-A20 catalog number, revision, quantity, destination and nameplate photo. Identification details will be checked before quotation.
Visit us
32D Guomao Building, No.388, Hubin South Road, Siming DistrictDisclaimer : Salesplcauto sells new and surplus products and develops channels for purchasing such products. This website has not been approved or recognized by any of the listed manufacturers or trademarks. Salesplcauto is not an authorized distributor, dealer, or representative of the products displayed on this website. All product names, trademarks, brands, and logos used on this website are the property of their respective owners. The description, explanation, or sale of products with these names, trademarks, brands, and logos is for identification purposes only and is not intended to indicate any association with or authorization from any rights holder.
Copyright @2026 SalesPlc Limited. Sitemap
/ Blog
/ XML
/ Terms And Conditions
/ Privacy Policy
Network Supported