Smart Link DP AC1335
AS-i to PROFIBUS DP Gateway · Single-master AS-i Version 2.1 gateway with a PROFIBUS DP fieldbus interface and local diagnostic display.
Lifecycle note: Use the unit nameplate and current official documentation as final references before approving a replacement.
Product Condition
Original New with One Year WarrantyParts Available
In Stock and Same Day ShippingDelivery Mode
Shipping via DHL Fedex or UPS etcEmail:
sales17@amikon.cnWhatsapp/Mob:
+86 15359408275AS-i to PROFIBUS DP Gateway · ifm AS-Interface Controllers and Gateways
ifm Smart Link DP AC1335 is an AS-Interface gateway that connects one AS-i Version 2.1 master network to a PROFIBUS DP control system.
The gateway exchanges sensor and actuator data with the higher control level and provides a backlit graphical display, four operating keys and four status LEDs for configuration and diagnostics.
Before installation, verify the AS-i power supply, PROFIBUS address and GSD configuration, AS-i slave addressing, functional earth, bus termination, DIN-rail mounting and cabinet temperature.
| Manufacturer | ifm electronic |
|---|---|
| Order number | AC1335 |
| Product name | Smart Link DP |
| Product type | AS-i / PROFIBUS DP gateway |
| AS-i masters | 1 |
| AS-i master version | 2.1 |
| PROFIBUS role | 1 PROFIBUS DP slave |
| Supply | From AS-i |
| AS-i current consumption | Less than 200 mA |
| AS-i operating voltage | 26.5 to 31.6 VDC |
| Display | Backlit 128 x 64 graphical LCD |
| Local controls | 4 function keys and 4 LEDs |
| Operating temperature | 0 to 60 deg C |
| Mounting | DIN rail |
| Housing | Aluminium / steel |
| Field terminals | Combicon screw terminals |
ifm Smart Link DP AC1335 exchanges AS-i sensor and actuator data with a higher-level controller through its PROFIBUS DP slave interface.
ifm Smart Link DP AC1335 contains one AS-i Version 2.1 master, so the installed slave addresses and AS-i power arrangement must match a single network.
ifm Smart Link DP AC1335 is supplied from AS-i at 26.5 to 31.6 VDC and has documented total AS-i current consumption below 200 mA.
ifm Smart Link DP AC1335 requires the correct PROFIBUS GSD configuration, station address, bus parameters and mapped AS-i slave data in the host controller project.
ifm AC1326 is a two-master gateway with a different supply arrangement, so it cannot directly replace ifm Smart Link DP AC1335 without redesigning the AS-i topology and controller configuration.
Installation of ifm Smart Link DP AC1335 requires DIN-rail security, functional-earth continuity, correct AS-i polarity, PROFIBUS termination, ventilation and a condensation-free 0 to 60 degree C environment.
Provide the complete ifm Smart Link DP AC1335 label, firmware or revision, PROFIBUS address and GSD version, AS-i slave count, quantity, condition and destination.
Send the complete Smart Link DP AC1335 catalog number, revision, quantity, destination and nameplate photo. Identification details will be checked before quotation.
Visit us
32D Guomao Building, No.388, Hubin South Road, Siming DistrictDisclaimer : Salesplcauto sells new and surplus products and develops channels for purchasing such products. This website has not been approved or recognized by any of the listed manufacturers or trademarks. Salesplcauto is not an authorized distributor, dealer, or representative of the products displayed on this website. All product names, trademarks, brands, and logos used on this website are the property of their respective owners. The description, explanation, or sale of products with these names, trademarks, brands, and logos is for identification purposes only and is not intended to indicate any association with or authorization from any rights holder.
Copyright @2026 SalesPlc Limited. Sitemap
/ Blog
/ XML
/ Terms And Conditions
/ Privacy Policy
Network Supported