1756-OF8I
8-Channel Isolated Analog Output Module · Eight individually isolated analog outputs configurable for voltage or current service.
Lifecycle note: Use the unit nameplate and current official documentation as final references before approving a replacement.
Product Condition
Original New with One Year WarrantyParts Available
In Stock and Same Day ShippingDelivery Mode
Shipping via DHL Fedex or UPS etcEmail:
sales17@amikon.cnWhatsapp/Mob:
+86 153594082758-Channel Isolated Analog Output Module · 1756 Modular Control I/O
1756-OF8I is an eight-channel analog output module whose channels are individually isolated and can be configured independently for voltage or current service.
The module supports bipolar and unipolar voltage ranges plus 0-20 mA current output, using 24-bit conversion and channel-level diagnostics for high-resolution process control.
Before replacement, preserve slot and module configuration, channel ranges and scaling, output limits, fault and hold behavior, field-power arrangement, terminal assembly and the controlled startup test.
| Model | 1756-OF8I |
|---|---|
| Product type | Isolated analog output module |
| Output channels | 8 individually isolated |
| Output modes | Voltage or current per channel |
| Voltage ranges | -10 to +10 V, 0 to 10 V, 0 to 5 V |
| Current range | 0 to 20 mA |
| Converter resolution | 24 bit |
| Voltage resolution | 0.32 mV/count at +/-10.5 V |
| Current resolution | 0.32 microampere/count at 0-21 mA |
| Backplane current at 5.1 V | 200 mA |
| Backplane current at 24 V | Up to 385 mA |
| Continuous isolation | 250 V output-to-backplane and output-to-output |
1756-OF8I supplies eight isolated analog commands to compatible actuators, positioners, converters or other field devices.
Each 1756-OF8I channel can be configured for -10 to +10 V, 0 to 10 V, 0 to 5 V or 0 to 20 mA service.
The individual isolation of 1756-OF8I reduces common-potential interaction between field loops, but site grounding and shielding rules still apply.
1756-OF8I supports per-channel voltage or current configuration, provided the terminal wiring and controller project match every selected range.
Preserve channel ranges, scaling, clamp limits, fault response, hold-last-state behavior, update settings and output ownership before replacing 1756-OF8I.
Commission 1756-OF8I by measuring every commanded output across its working range, checking diagnostics and proving the connected field device response.
Provide the complete 1756-OF8I label, hardware and firmware revision, terminal assembly, channel-range schedule, quantity and destination.
Send the complete 1756-OF8I catalog number, revision, quantity, destination and nameplate photo. Identification details will be checked before quotation.
Visit us
32D Guomao Building, No.388, Hubin South Road, Siming DistrictDisclaimer : Salesplcauto sells new and surplus products and develops channels for purchasing such products. This website has not been approved or recognized by any of the listed manufacturers or trademarks. Salesplcauto is not an authorized distributor, dealer, or representative of the products displayed on this website. All product names, trademarks, brands, and logos used on this website are the property of their respective owners. The description, explanation, or sale of products with these names, trademarks, brands, and logos is for identification purposes only and is not intended to indicate any association with or authorization from any rights holder.
Copyright @2026 SalesPlc Limited. Sitemap
/ Blog
/ XML
/ Terms And Conditions
/ Privacy Policy
Network Supported