RDCO-02C 3ABD64606956
Coated DDCS Communication Module · Coated four-channel DDCS fiber-optic communication option for compatible RMIO or BCU drive control hardware.
Lifecycle note: Use the unit nameplate and current ABB documentation as final references before approving a replacement.
Product Condition
Original New with One Year WarrantyParts Available
In Stock and Same Day ShippingDelivery Mode
Shipping via DHL Fedex or UPS etcEmail:
sales17@amikon.cnWhatsapp/Mob:
+86 15359408275Coated DDCS Communication Module · ABB ACS800 and Compatible Drive Control Units
ABB RDCO-02C 3ABD64606956 is the coated version of the RDCO-02 DDCS communication option module. It adds four fiber-optic DDCS channels to compatible RMIO motor-control boards or BCU control units.
RDCO-02C provides 5 MBd optical components on CH0 and CH1 and 10 MBd components on CH2 and CH3. Channel use is assigned by the installed drive application and firmware rather than by the physical connectors alone.
Before replacement, verify the coated C-version, control-unit compatibility, channel node addresses, fiber type and direction, optical component rates, application assignments and drive parameter backup.
| Manufacturer | ABB |
|---|---|
| Module type | RDCO-02C |
| Order reference | 3ABD64606956 |
| Product type | DDCS communication option |
| Circuit board | Coated C-version |
| Channels | CH0, CH1, CH2 and CH3 |
| CH0 optical rate | 5 MBd |
| CH1 optical rate | 5 MBd |
| CH2 optical rate | 10 MBd |
| CH3 optical rate | 10 MBd |
| Mounting interface | RMIO motor-control and I/O board or compatible BCU control unit |
| Typical roles | Overriding system, I/O options, Master/Follower and PC tool |
ABB RDCO-02C 3ABD64606956 adds four fiber-optic DDCS channels to a compatible RMIO or BCU drive control unit.
The C suffix identifies the coated circuit-board version, so it should be matched when environmental protection or the original drive build requires the coated option.
ABB RDCO-02C 3ABD64606956 uses 5 MBd optical components on CH0 and CH1 and 10 MBd components on CH2 and CH3.
Channel use depends on the drive application, but CH0 commonly serves an overriding system, CH1 I/O options, CH2 Master/Follower communication and CH3 a PC tool.
Another RDCO type may use different optical rates, so every channel assignment, connected node and application requirement must be checked before substitution.
Provide the complete module and order references, drive and control-unit models, firmware, channel assignments, optical network layout, quantity and destination.
Send the complete model, revision, quantity, destination and nameplate photo so the exact hardware identity can be checked.
Visit us
32D Guomao Building, No.388, Hubin South Road, Siming DistrictDisclaimer : Salesplcauto sells new and surplus products and develops channels for purchasing such products. This website has not been approved or recognized by any of the listed manufacturers or trademarks. Salesplcauto is not an authorized distributor, dealer, or representative of the products displayed on this website. All product names, trademarks, brands, and logos used on this website are the property of their respective owners. The description, explanation, or sale of products with these names, trademarks, brands, and logos is for identification purposes only and is not intended to indicate any association with or authorization from any rights holder.